Installation/Operation Supplement
15
70278501 (EN)
Gas Requirements
Natural Gas and Liquefied Petroleum
IMPORTANT: Any product revisions or 
conversions must be made by the Manufacturer’s 
Authorized Dealers, Distributors, or local service 
personnel.
IMPORTANT: The tumbler must be isolated from 
the gas supply piping system by closing its 
individual manual shut-off valve during any 
pressure testing of the gas supply piping system at 
test pressure equal to or less than 3.45 kPa, 
34.5 mbar (0.5 psi).
IMPORTANT: The tumbler and its manually 
operated appliance gas valve must be disconnected 
from the gas supply piping system during any 
pressure testing of that system at test pressures in 
excess of 3.45 kPa, 34.5 mbar (0.5 psi).
IMPORTANT: The installation must comply with 
local codes.
NOTE: This manual is only a supplement. Refer to 
installation/operation manual for full instructions.
To reduce the risk of fire or explosion, DO 
NOT CONNECT THE GAS LINE TO THE 
TUMBLER IF THE GAS SERVICE IS NOT 
THE SAME AS THAT SPECIFIED ON THE 
TUMBLER SERIAL PLATE! It will first be 
necessary to convert the gas burner 
orifice and gas valve. Appropriate 
conversion kits are available.
W060
WARNING
To reduce the risk of fire or explosion, if 
the tumbler is to be connected to 
Liquefied Petroleum (L.P.) gas, a vent to 
the outdoors must be provided in the room 
where the tumbler is installed.
W062
WARNING