Alliance Laundry Systems d355ie1b Manual De Usuario

Descargar
Página de 88
30
504524
• Main collector duct should be sized according to 
specifications shown below.
NOTE: Main collector duct should be equipped with 
an auxiliary fan that can maintain the duct airflow at 
a minimum of 1200 feet (366 m) per minute. If you do 
not have a fan, clean the main collector duct at least 
twice a year.
D039IE3A
WEATHER HOOD
OR SWEEP ELBOW
(No cap or screen)
WALL
PARAPET
ROOF
180˚ SWEEP
ELBOW
(No cap
or screen)
24" MIN.
(60.96 cm)
VERTICAL DUCT
HORIZONTAL DUCT
MAIN COLLECTOR DUCT
MAIN COLLECTOR DUCT
Number
of Dryers
Minimum Diameter of
Horizontal Collector Duct
Minimum Diameter of
Vertical Collector Duct
1 stack
 7 inch (17.8 cm)
 8 inch (20.3 cm)
1 stack
 8 inch (20.3 cm)
 9 inch (22.9 cm)
2 stacks
 9 inch (22.9 cm)
10 inch (25.4 cm)
2 stacks
10 inch (25.4 cm)
11 inch (27.9 cm)
3 stacks
11 inch (27.9 cm)
12 inch (30.5 cm)
3 stacks
12 inch (30.5 cm)
13 inch (32.6 cm)
4 stacks
12 inch (30.5 cm)
14 inch (35.6 cm)
4 stacks
13 inch (32.6 cm)
15 inch (38.1 cm)
5 stacks
14 inch (35.6 cm)
15 inch (38.1 cm)
5 stacks
14 inch (35.6 cm)
16 inch (40.6 cm)