8) 
Carefully insert the replacement motor unit into the cylinder by ensuring that the couplings do not lose 
their alignment. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
9) 
Using an Allen wench of 2 mm across flats, tighten the two motor-unit affixing bolts on the right and 
left. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
10)  Connect a PC or teaching pendant to the controller to perform homing. (If the actuator is of absolute 
encoder specification, an absolute reset must be performed). 
Check for deviation from the initial home position.   
If there is a deviation, adjust parameter No. 22, “Home offset” if you are using an SCON controller. If 
you are using an SSEL or X-SEL controller, adjust axis-specific parameter No. 12, “Home preset.” If 
your controller is of absolute encoder specification, perform homing after changing the parameter, 
and then perform an absolute reset. 
 
2 affixing bolts on the motor-end 
cap (right and left) (hexagon 
socket head setscrews)