Chapter 5: Management with WebPAM PRO
147
Running Redundancy Check
Redundancy Check is a routine maintenance procedure for fault-tolerant disk 
arrays (those with redundancy) that ensures all the data matches exactly. 
Redundancy Check can also correct inconsistencies. You can also schedule a 
Redundancy Check. See “Scheduling an Activity” on page 111.
Redundancy Check a Logical Drive:
1.
Click the Subsystem 
 icon in Tree View. 
2.
Click the Logical Drive Summary   icon. 
3.
Click the   icon of the logical drive you want to Redundancy Check. 
4.
From dropdown menu on the Background Activities tab, choose 
Redundancy Check
To  choose  Auto Fix, check the box.
This feature attempts to repair the problem when it finds an error. 
To  choose  Pause On Error, check the box.
This feature stops the process when it finds an error.
If Auto Fix is also checked, the process stops only when it finds a non-
repairable error. 
5.
Click the Submit button. 
To view the progress of the Redundancy Check, click the Background Activity 
tab.
To set Redundancy Check priority, see “Making Background Activity Settings” on 
page 109.
You can also start Redundancy check from the Subsystem 
 icon Background 
Activities tab
Viewing the Logical Drive Check Table
The Logical Drive Check Table displays errors related to a logical drive. Use this 
information to evaluate the integrity of the logical drive and to determine whether 
corrective action is needed. To View the tables: 
1.
Click the Subsystem 
 icon in Tree View. 
2.
Click the Disk Arrays 
 icon. 
3.
Click the Disk Array   icon. 
4.
Click the Logical Drives   icon
5.
Click the Logical Drive   icon.