Promise Technology EX8650A Manual De Usuario

Descargar
Página de 232
SuperTrak EX Series User Manual
188
The physical drive in channel 2 fails. The disk array becomes degraded and its 
logical drives go critical. The SuperTrak controller automatically rebuilds the disk 
array using the spare drive, the physical drive in channel 4. 
As we saw in the example of Automatic Transition, if you replace the failed 
physical drive in channel 2, the SuperTrak controller would transition the data 
from the physical drive in channel 4 to the new drive in channel 2.
But if you wanted to use a different physical drive in your array, such as the 
unassigned drive in channel 3, you would run the Transition function manually
When the Manual Transition is finished:
The physical drives in channels 1 and 3 belong to the disk array. 
The physical drive channel 2 is still failed and unusable.
The physical drive in channel 4 is a revertible spare drive. 
At this point, after running the Manual Transition, you would replace the failed 
drive in channel 2. The replacement drive in channel 2 will remain unconfigured 
until you assign it to a disk array or as a spare.