Polycom kirk wireless server 6000 Manual De Usuario

Descargar
Página de 323
NetEngine IAD User Guide
Troubleshooting and Diagnostics
268
Cannot receive or send 
data
Incorrect PVC/DLCI 
set for data channel
Verify these settings:
VPI: 0 to 255
VCI: 0 to 65535
DLCI: 16 to 1023
(default PVC 0/38; DLCI 
32)
View Interface 
(page
) and Media 
statistics (page
) to 
check the pack receive 
and send status.
Incorrect network 
setup
Check and correct 
network setup as 
necessary.
If IAD is configured as 
router:
Incorrect or missing 
LAN or WAN IP 
address
Ensure that both the LAN 
and WAN IP addresses 
are configured.
Incorrect or missing 
default static route
Review the routing table 
and correct as necessary 
(page
).
Incompatible  RIPv1 Check and correct subnet 
masks (255.255.255.0)
Update RIPv1 to RIPv2.
If the IAD is configured 
as a bridge:
incorrect bridging 
parameters
Review IAD configuration 
(page
) and current 
bridge status (page
).
Correct as necessary
Incorrect 
connection
Ensure that the IAD is 
connected to another 
bridge
Missing peer or 
converter
Install a converter to 
convert 1483 cells to 
Ethernet packets.
Table 14–1.Troubleshooting—Symptoms and Causes
Symptom
Probable Cause
Corrective Action