Chapter 7 - Diagnostics and General Troubleshooting
© Polycom, Inc.
7-17
The system displays 
an error message 
when you place an IP 
call.
All
The system is not connected 
to the LAN.
Verify that the system’s LAN cable is 
connected properly.
The system’s LAN cable is 
bad.
Replace the system’s LAN cable.
The far site is not available.
Use the ViewStation web interface to 
run the Ping test (Set Up System> 
Diagnostics > Ping
) to determine 
whether the far site is accessible to 
your system. If the test fails, the far site 
system is unavailable.
The system is not configured 
correctly for the network.
Check your IP configuration. For 
detailed instructions, se
.
The IP Gateway/Gatekeeper 
is not operating or is not 
configured correctly.
Contact your network administrator.
The PBX does not 
accept calls of type 
“unknown” from the 
PRI network 
interface module
All
The PRI network interface is 
not configured correctly
Verify that you have configured the 
system’s PRI network interface 
correctly. For detailed instructions, see 
A system using a 
V.35/RS-449/RS-530 
interface cannot 
receive calls at 
certain speeds
All
V.35/RS-449/RS-530 systems 
cannot determine how to 
allocate bandwidth for call 
speeds that are divisible by 
both 56 and 64 (such as 448K: 
8 x 56K), so the call cannot be 
connected correctly.
Call the far site, or have the caller try 
again at a different call speed.
Cannot select 112 or 
128 speeds for 
bonding calls from 
the speed selection.
All
These speeds do not show 
when you select the speed 
icon.
Add line speeds on the Admin 
Settings > Video Network > Dialing 
Speeds
 screen.
Cannot complete 
calls to sites that do 
not use encryption
All
The system displays a 
message stating that 
encryption is required.
Your system is configured to require all 
calls to be encrypted, and encryption is 
not available at the far site.
Symptom
System
Cause
Solution