Phihong PSA16U-480(POE) Manual De Usuario

Descargar
Página de 3
PSA16U 480(POE) Led Function 
 
WWW.PHIHONG.COM
 
 
Power Injector Block Diagram 
 
Description of LED Functions for Power Injector 
Power-up Sequence: 
Upon  power-up,  all  3  LEDs  will  light  for  2  seconds,  as  part  of  the  self-test  for  the  internal 
microprocessor  software.    After  the  2  second  period,  the  "ON"  LED  will  illuminate  green.  The  DC 
output voltage is now available for powering a compliant load (to the 802.3af PoE standards). 
 
Detection Sequence: 
 
Once  a  compliant  load  is  attached  to  the  output  RJ45  connector,  the  green  "CONNECT"  LED  will 
illuminate. 
 
Should  the  load  be  non-compliant  then  the  LEDs  will  blink  a  code  specific  to  the  cause  for  non-
detection. 
 
Detection Failure Codes: 
 
1.  Incorrect resistive signature – The green “CONNECT” and red “FAULT” LEDs will blink 3 times. 
2.  Incorrect capacitive signature – The green “ON” LED will blink 3 times. 
3.  Incorrect Voffset – The green “CONNECT” and green “ON” LEDs will blink 3 times. 
4.  Unstable current measurement – The green “ON” LED will blink 3 times 
5.  Low voltage sensed during detection (overload) – The red “FAULT” LED will blink 3 times 
 
After the LEDs blink 3 times the Power Injector will continue to try to detect a valid load.  Until the 
correct  load  is  applied,  the  LEDs  will  continue  to  blink.    If  there  is  an  open  circuit  connected  to  the 
output RJ45 then the LEDs will not blink but the Power Injector will continue to try to detect a valid 
load.  
 
Fault Sequence: 
Should there be a fault such as an overload or short circuit then the red "FAULT" LED will illuminate.  
The red “FAULT” LED will illuminate for 2 seconds and then go off as the power supply tries to re-
detect a valid load.  If there is a problem detecting the load, the LEDs will indicate a possible fault as 
per the codes in the section above.
 
RJ45 
Data 
IN 
 
 
 
RJ45 
Data 
Power 
Out 
PoE 
Power & 
Control 
On 
 
Power 
 
Connect