GarrettCom 6K8 Manual De Usuario

Descargar
Página de 76
Magnum 6K8-Series Industrial Field Switch             Installation and User Guide   (04/07) 
 
Figure 3.6.1d:  Removing PM screens Plate 
www  GarrettCom  com
.
.
Once opened all the four retaining 
screws the front cover can be removed 
easily as shown in Fig 3.6.1d. (To the 
left).  
 
Carefully remove the PM screen plate 
using finger or small screwdriver to 
come out easily as shown in Fig 
3.6.1d on the right. Just be careful on 
the LEDs placed both side and hold 
the faceplate tightly. There are no screws used on 
holding the screen faceplate
 
 
Figure 3.6.1d:  Removing Face Plate 
 
 
 
3.6.2 
Installing 6KPM Cards in the Magnum 6K8-Series 
 
Only one front-mounted 6KPMV Module may be installed in one Magnum 
6K8-Series Field Switch unit. Follow these steps to install a 6KPMV. 
Step 1.  Remove top 
chassis cover. See 
procedure in Section 
3.6.1 above.  
 
Fig 3.6.2a A Magnum 6K8 
unit with main board 
(motherboard) only 
 
Step 2.  Place Granddaughter board (as shown in fig. 
3.6.2b) on the chassis built in stand off (female) 
provided at the front of the 6K8-Series Main Board.  To 
place the Granddaughter board  
 
 
Fig 3.6.2b Granddaughter Board shown separately 
 
on the chassis, as shown in Figure below 3.6.2c, screw down tightly with the three 5/16 
stand off (male) on the top of the Granddaughter board. The three 5/16 stand off has been 
used to place the daughter board on the top of the granddaughter board and a latch 
 
 
38