GarrettCom 6K8 Manual De Usuario
Magnum 6K8-Series Industrial Field Switch Installation and User Guide (04/07)
3.7.1
RS-232 (DB-9) Console Com port (Serial port) pin assignments.
Pin 1
Pin 5
DB-9 (Console port connector)
Pin
Signal
Description
1
CD
Carrier
detect
(not
used)
2
RXD
Receive
Data
(input)
3
TXD
Transmit
Data
(output)
4
open
not
used
5
GND
Signal
Ground
6-9
open
not
used
The above information enables a management station (a PC or Console terminal) to
connect directly to the Switch Console using a straight-through serial cable.
NOTE for Power Substations: In support of the IEEE 1613 Class 2 standard, GCI
advises that, for substation applications, the serial RJ-45console ports are
intended for temporary connectivity to other equipment such as PCs. Since the
console port connection is temporary, it is excluded from IEEE 1613 packet-
loss testing per the 1613 standard-defined test procedure.
intended for temporary connectivity to other equipment such as PCs. Since the
console port connection is temporary, it is excluded from IEEE 1613 packet-
loss testing per the 1613 standard-defined test procedure.
4.0 OPERATION
This chapter describes the functions and operation of the Magnum 6K8-Series
Switch.
4.1 Switching
Functionality
A Magnum 6K8-Series provides switched connectivity at Ethernet wire-speed
among all of its ports. The Magnum 6K8-Series supports10/100Mbs for copper media
and 10 or 100Mb separate traffic domains for fiber ports to maximize bandwidth
utilization and network performance. All ports can communicate to all other ports in a
Magnum 6K8-Series, but local traffic on a port will not consume any of the bandwidth
on any other port.
and 10 or 100Mb separate traffic domains for fiber ports to maximize bandwidth
utilization and network performance. All ports can communicate to all other ports in a
Magnum 6K8-Series, but local traffic on a port will not consume any of the bandwidth
on any other port.
43
www GarrettCom com
.
.