Table 4. Video Input Timing. 
Symbol Name 
Min 
Max 
Units 
T1 
Frame time 
8.3 
 --- 
ms 
 
Frame frequency 
 --- 
120 
Hz 
T2 
CP1 High time 
60 
 --- 
ns 
T3 
CP1 Period 
34.5 
 --- 
µs 
 
 
S (FRAME)
CP1 (LINE)
UD0 to UD3
LD0 to LD3
CP2 (SHIFT)
tSU
tHOLD
tF
tR
tS21
tS12
tF
tR
tSU
tHOLD
tS3
tCLK
tCL
tCH
 
Figure 3. Setup and Hold Timing Diagram.
 
 
Table 5. Setup and Hold Timing. 
Symbol Name 
Min. 
Max 
Unit 
tS21 
CP1 allowance from CP2 
 
ns 
tS12 
CP2 allowance from CP1 
200 
 
ns 
tS3 
CP1 allowance to CP2 
50 
 
ns 
tSU Setup 
time 
50 
 
ns 
tHOLD Hold 
time 
40 
  ns 
tR Rise 
time 
 
30 
ns 
tF Fall 
time 
 
30 
ns 
tCLK 
CP2 clock cycle 
154 
 
ns 
tCL 
CP2 clock low time 
60 
 
ns 
tCH 
CP2 clock high time 
60 
 
ns