Planar el640.480-af1 Manual De Usuario
EL640.480-AF1 VGA Operations Manual (020-0349-00A)
11
Reliability
The MTBF (mean time between failure) is a minimum of 50,000 hours at 25°C
ambient, except for performance characteristics with an otherwise specified
life expectancy.
ambient, except for performance characteristics with an otherwise specified
life expectancy.
Safety and EMI
The display will not inhibit the end product from obtaining these certifications:
Safety UL544,
IEC950
EMI
FCC Part 15/J, Class B
EN55022 Level B
EN55022 Level B
Environmental
Table 7. Environmental Characteristics.
Temperature
Operating
Non-Operating
Operating Survival
Non-Operating
Operating Survival
-5 to +55°C
-40 to +75°C
-20 to +65°C
-40 to +75°C
-20 to +65°C
Humidity
Non-condensing
93% RH max, @ 40°C
per IEC 68-2-3.
Altitude
Operating
Non-Operating
Non-Operating
0 to 5 km (16k ft)
0 to 18 km (58k ft)
0 to 18 km (58k ft)
per IEC 68-2-13.
Vibration
Random
0.05 g²/Hz
ASD level, 20-500 Hz per
IEC 68-2-36, test Fdb
IEC 68-2-36, test Fdb
Shock
Half sine wave
100 g, 4 ms
18 (3 each, 6 surfaces) per
IEC 68-2-27, test Ea
IEC 68-2-27, test Ea