Reliability 
The MTBF (mean time between failure) is a minimum of 50,000 hours at 25°C 
ambient, except for performance characteristics with an otherwise specified 
life expectancy. 
Safety and EMI 
The display will not inhibit the end product from obtaining these certifications: 
Safety UL544, 
IEC950 
EMI 
FCC Part 15/J, Class B 
EN55022 Level B 
Environmental  
Table 7. Environmental Characteristics. 
Temperature 
 
Operating  
Non-Operating 
Operating Survival 
-5 to +55°C 
-40 to +75°C 
-20 to +65°C 
Humidity 
Non-condensing 
93% RH max, @ 40°C 
per IEC 68-2-3. 
Altitude 
Operating 
Non-Operating 
0 to 5 km (16k ft) 
0 to 18 km (58k ft) 
per IEC 68-2-13. 
Vibration 
Random 
0.05 g²/Hz 
ASD level, 20-500 Hz per 
IEC 68-2-36, test Fdb 
Shock 
Half sine wave 
100 g, 4 ms 
18 (3 each, 6 surfaces) per 
IEC 68-2-27, test Ea