The following steps describe how to properly install the cables for an OCIA StratosS application.  The scanner/Avery scale 
must then be configured to match the host’s OCIA parameters.  Cable installation alone does not guarantee that the StratosS 
will communicate properly with the host system. 
 
Configuration bar codes are located in the MetroSelect Configuration Guide
 
(
MLPN
 00-02407
x) and the  
MS2
xxx Stratos Series Configuration Addendum (
MLPN
 00-02034
x). 
 
 
1.  Turn off the host system. 
 
2.  Plug the 10-pin RJ45 end of the OCIA interface cable (
MLPN
 57-57016
x-N-3) into the 10-pin socket labeled Scanner Host 
OCIA on the bottom of the StratosS.  Refer to figure on page 25. 
 
3.  Connect the other end of the OCIA Interface cable (
MLPN
 57-57016
x-N-3) to the appropriate communication port on the 
host device. 
 
Before continuing verify that the OCIA cable pinouts match the host system’s and is connected to the appropriate 
interface socket on the scanner.  An incorrect cable connection can cause communication problems or potential 
damage to the scanner and/or terminal.   
 
Manufacturers Note:  Plugging the scanner into the serial port of the host device does not guarantee that scanned 
information will appear at the host device.  A software driver and correct configuration settings are also required for 
proper communication to occur. 
 
Steps 4 and 5 are for dual cable interfaces where the scale and the scanner connect to the host with their own separate 
communication cables. Skip to step 6 for a single cable interface where the scale and scanner connect to the host with a 
single cable. 
 
4.  Plug the dual interface cable (
MLPN
 57-57000
x-N-3) into the 10-pin socket labeled Scale RS232 to Host, on the bottom of 
the StratosS
 
5.  Connect the other end of the dual interface cable (
MLPN
 57-57000
x-N-3) to the appropriate communication port on the 
host’s scale device. 
 
6. Plug 
the 
optional remote display cable (
MLPN
 46-00248
x or 46-00249x) into the 10-pin socket labeled Scale to Display 
on the bottom of the StratosS
 
7.  Plug the external power supply (
MLPN
 46-002
xx) into the 3-pin Molex socket labeled, DC Power In, on the bottom of the 
StratosS
 
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet.  The outlet 
should be located near the equipment and be easily accessible. 
 
Metrologic recommends using a switched AC outlet.  The switch should be located on the operator’s side of the 
checkout counter in close proximity to the StratosS to facilitate calibration and service of the unit. 
 
8.  Connect AC power to the transformer.  If the AC outlet is equipped with an on/off switch, turn the power on. 
 
9.  Turn on the host system.