Maytag mat12psa Manual De Usuario

Descargar
Página de 29
16
16022842  Rev. 0
©2003 Maytag Appliances Company
WARNING
!
To avoid risk of electrical shock, personal injury or death;
disconnect power to unit before servicing.
Disassembly Procedures
CS (Coin Slide) Model Timer
1.  Disconnect power supply to unit.
2. Use key to gain access through service door.
3. Remove screw securing timer bracket to meter case.
4. Lift timer and bracket up and forward from the meter
case.
Note:
Extra wire (slack) can be fed from the left.
Control Panel
1. Disconnect power supply to unit.
2. Remove top two T-20H Torx  screws located on the
front of the control panel.
3. Carefully lay  the control panel forwards.
 Note: Use a protective cloth to minimize the chance
of scratching the panel on the control console.
Control Board (Microprocessor)
1. Disconnect power supply to unit.
2. Remove Control Panel.
3. Remove four 5/16” nuts from backup plate mounting
studs.
4. Lift board from studs and tilt forward.  Don’t lose the
spacers.
5. Disconnect touch pad ribbon.  Grasp touch pad “tail”
between your thumbs and forefinger.  Ribbon can be
pulled out of receptacle.
5. Squeeze tabs to remove connectors from timer.
MN (Manual) Model Timer
1. Disconnect power supply to unit.
2. Carefully pry the timer knob center cap out of the
knob.
3. Slip the retainer clip off of the timer shaft.
4. Pull the knob, spring and dial off of the timer shaft.
5. Remove screws securing Timer to Control Panel.
6. Remove Control Panel.