Crestron electronic TPS-IMPC Manual De Usuario
Crestron TPS-IMPC
Interface
Module
Industry Compliance
As of the date of manufacture, the TPS-IMPC has been tested and found
to comply with specifications for CE marking and standards per EMC
and Radiocommunications Compliance Labelling (N11785).
to comply with specifications for CE marking and standards per EMC
and Radiocommunications Compliance Labelling (N11785).
Setup
Network Wiring
CAUTION: Use only Crestron power supplies for Crestron equipment.
Failure to do so could cause equipment damage or void the Crestron
warranty.
Failure to do so could cause equipment damage or void the Crestron
warranty.
CAUTION: Possible equipment damage if miswired.
NOTE: When installing network wiring, refer to the latest revision of the
wiring diagram(s) appropriate to your specific system configuration,
available from the Downloads | Product Manuals | Wiring Diagrams
section of the Crestron website (www.crestron.com).
wiring diagram(s) appropriate to your specific system configuration,
available from the Downloads | Product Manuals | Wiring Diagrams
section of the Crestron website (www.crestron.com).
NOTE: Do not power up system until all wiring is verified. Care should
be taken to ensure data (Y, Z) and power (24, G) connections are not
crossed.
be taken to ensure data (Y, Z) and power (24, G) connections are not
crossed.
NOTE: All network wiring must consist of two twisted-pairs. One
twisted pair is the +24V conductor and the GND conductor and the other
twisted pair is the Y conductor and the Z conductor.
twisted pair is the +24V conductor and the GND conductor and the other
twisted pair is the Y conductor and the Z conductor.
NOTE: For larger networks (i.e., greater than 28 network devices), it
may be necessary to add a Cresnet Hub/Repeater (CNXHUB) to maintain
signal quality throughout the network. Also, for networks with lengthy
cable runs or varying types of network devices, it may be desirable to add
a hub/repeater after only 20 network devices.
may be necessary to add a Cresnet Hub/Repeater (CNXHUB) to maintain
signal quality throughout the network. Also, for networks with lengthy
cable runs or varying types of network devices, it may be desirable to add
a hub/repeater after only 20 network devices.
When calculating the wire gauge for a particular network run, the length
of the run and the power factor of each network unit to be connected
of the run and the power factor of each network unit to be connected
Operations Guide - DOC. 6162
Interface Module: TPS-IMPC
• 7