GE simon 60-875 Manual De Usuario

Descargar
Página de 36
Simon Security System
21
4.
Press Option #. Panel announces, Option 1, press again for next option or done to 
select.
5.
Press 81. Panel announces, Option 81, press again for next option or done to delete.
6.
Press DONE. Panel announces, Option 81 deleted.
Option 82: Cooling Set Point
When this option is on you can set a temperature that will automatically turn the air con-
ditioner on if the temperature rises above the set temperature. The commands are set 
through the control panel, to the RF Electronic Thermostat, when the system is armed to 
level 4.
Note  
RF Thermostat must be in 
Cool Mode or Auto Mode for 
the option to work properly.
Add allows you to set the temperature from 51°F - 91°F.
1.
Open panel cover. Panel announces, Use numbered keys to enter ID. 
2.
Enter Master Code using the numbered keys. Panel announces, Please select from 
Start Menu.
3.
Press Add from the Start menu. Panel announces, Select from main menu.
4.
Press Option #. Panel announces, Option 1, press again for next option or done to 
select.
5.
Press 82. Panel announces, Option 82, press again for next option or use numbered 
keys to enter option.
6.
Enter the temperature (51 - 91) with the numbered keys.
7.
Panel announces the temperature that has been selected.
Delete deletes the Cooling Set Point feature.
1.
Open panel cover. Panel announces, Use numbered keys to enter ID. 
2.
Enter Master Code using the numbered keys. Panel announces, Please select from 
Start Menu.
3.
Press Delete from the Start menu. Panel announces, Select from main menu.
4.
Press Option #. Panel announces, Option 1, press again for next option or done to 
select.
5.
Press 82. Panel announces, Option 82, press again for next option or done to delete.
6.
Press DONE. Panel announces, Option 82 deleted.
Trouble Beeps
Your security system is able to automatically test itself for: 
Power failures
Low batteries
Non-working sensors
Communication troubles with the Central Monitoring Station
When your security system detects one of the problems above, six rapid beeps sound 
every minute, until the trouble condition is corrected.
AC Power Failure
This condition occurs if your security system has been accidentally unplugged or if 
there has been an AC power outage. The backup battery will take over. If AC power is 
not restored within 15 seconds, the panel will go dark and alert you with trouble beeps. 
If you press any button, the display will light and pressing SYSTEM STATUS will 
confirm the AC power failure. If AC power is not restored within a programmed period 
of time (5-254 minutes) the system will call the central monitoring station (if pro-
grammed by installer). The backup battery, if fully charged, will last for 18 - 24 hours, 
depending on the load applied to the panel, with no AC power.
Silencing Trouble Beeps
To stop the trouble beeps, press the SYSTEM STATUS button or arm/disarm the sys-
tem while the trouble condition exists. Trouble beeps will begin 4 hours later, unless 
the trouble condition is corrected.