gml gml8200 Manual De Usuario

Descargar
Página de 14
Specification Notes
1
 All tests conducted using the Audio Precision System Two Cascade Dual Domain (AP S2C), unless
otherwise noted.  Individual unit performance may vary due to environmental influences, manufacturing
variations, and component tolerances.
2
 CMRR determined by calculating the average of 500 individual spot measurements generated by a
logarithmic frequency sweep from 20 kHz to 20 Hz.
3
 CMRR determined by AP S2C analyzer reading, including bandpass filter from <10 Hz to >500 kHz.
4
 As determined by THD+N in excess of 0.1%.
5
 All bandwidth tests were conducted at 0 dBu, EQ In, all bands flat.
6
 Includes AP S2C residual THD of 0.0007%.  Test conducted with 1.0 kHz sine at +20 dBu.
7
 Includes AP S2C residual IMD of 0.0015%.  Test conducted with 1.0 kHz SMPTE/DIN 4:1 at +20 dBu.
8
 GML 9202
9
 Spot noise measurements were determined in 500-point logarithmic frequency sweeps, including
bandpass filter (<10 Hz to >500 kHz) to measure the individual noise contributions of those frequencies to
the broadband figure.  The spot noise specification noted is an average of these individual contributions
from 20 Hz to 20 kHz.
Broadband measurements were determined by the AP S2C analyzer, full bandwidth.
10
 Includes AP S2C residual crosstalk of -140 dBu.  Test conducted at +20 dBu, 20 Hz to 20 kHz.
11
 Actual weight.  Shipping weight is approximately 8 lbs.