PROGRAMMING THE BREWER (cont.)
CALIBRATE FLOW (cont.)
Procedures to calibrate the bypass flow rate:
1.  Place a container, accurately graduated in ounces, 
and with a minimum capacity of 60 ounces, below 
the funnel on the brewer to be calibrated.
2.  Press and hold the upper right hidden switch until 
the display reads UNITS. Release the switch. Con-
tinue to press and release switch until the display 
reads CALIBRATE FLOW?.
3.  Press and release YES to advance to the SPRAY 
HEAD CAL? function screen. (Pressing NO in the 
CALIBRATE FLOW screen will advance to the next 
function screen, BREW COUNTERS).
4.  Press and release NO to advance to the BYPASS 
CALIBRATION screen.
5.  Press and release YES. The display should read 
CONTAINER READY? If the container is under the 
funnel, press YES. The display should read CALI-
BRATE BYPASS .. PRESS BREW TO START.
6.  Press and release the BREW switch (on the side 
to be calibrated on DUAL brewers). The display 
should read CALIBRATE BYPASS .. 60 SEC TO 
FINISH. The 60 second timer on the display will 
count down to zero. When the counter reaches 
zero, the display will change to:
 
ENTER OZ. (SINGLE brewers)
 
LEFT or RIGHT OZ. (DUAL brewers), along with 
a number.
7.  Measure the amount of water in the container, and 
using (-) or (+), adjust the amount on the display 
to match the amount in the container. Then press 
DONE.
8.  The display should now read:
 
NEW BYPS FLOW (SINGLE brewers)
 
NEW L or R BYPS FLOW (DUAL brewers), along 
with the correct flow rate of the bypass in ounces 
per minute. After about 5 seconds, the display will 
return to the CALIBRATE FLOW screen.
9.  Repeat steps 1 - 9 when calibrating the other side 
for DUAL brewers. 
10. To exit the CALIBRATE FLOW function, press and 
release NO to advance to next function screen, or 
press and release the ON/OFF switch (either on 
DUAL brewers) located on the front switch panel 
to exit the CALIBRATE FLOW function and return 
to the MAIN SCREEN.
CALIBRATE BYPASS
PRESS BREW START
NEW L BYPS FLOW
XX.X  OZM
LEFT OZ XX.X
(-)      DONE      (+)
NEW BYPS FLOW
XX.X  OZM
OZ XX.X
(-)      DONE      (+)
5 sec
5 sec
CALIBRATE FLOW?
NO                   YES
SPRAYHEAD CAL?
NO                   YES
CONTAINER READY?
NO                   YES
BYPASS  CAL?
NO                   YES
CALIBRATE SPRAY
60  SEC  TO  FINISH
BREW PRESSED
COUNTS DOWN 
TO ZERO
AFTER 1 MINUTE
Left or Right
L or R
SINGLE
BREWERS
DUAL
BREWERS
EXIT TO
NEXT FUNCTION
SCREEN
41342 080108