Maintenance and Troubleshooting
52 
 800032-01 Rev. G 
www.wegener.com
frequency (for domestic C-band satellites, this is 5150 minus the downlink frequency in 
MHz). To rule out (2), try connecting the RF cable to another RF port and select that port (or 
use RF Switch Bypass to force that other port). To rule out (3), try using another IRD.
2.
If the first alarm message is “No Carrier Lock”, verify the RF Feed Port, Carrier Frequency, 
Data Rate, FEC Ratio, and ID Tag (if Tags are in use) settings. Also verify that the LNB LO 
frequency setting (in the IRD) is correct for the selected RF feed port.
3.
If the alarm message is “RF signal overload”, then reduce the carrier power entering the 
Unity 4600
. Either add in-line attenuation (a splitter will do) or remove line amplification in 
the RF circuit between the LNB and the IRD.
LEDS: 
ALARM
 ON and 
CARRIER
 ON
The 
Unity 4600
 may not be authorized for the network’s Conditional Access. If the 
AUTH
 
LED is OFF and the alarm message, "Unauthorized for CA” appears, contact your network 
provider to gain authorization in its Conditional Access database.
Missing an 
audio, video, 
or ASI output 
while others 
are okay
LEDS: 
ALARM
 or 
WARNING
 ON
Check the front-panel display for alarm or warning messages. 
Unity 4600
 alarm and warning messages. If 
the message definitions are too technical to help debug the problem, report the messages 
to your network provider.
LEDS: 
ALARM
 and 
WARNING
 OFF
If no alarms or warnings are shown, suspect a bad connection or mis-programming of the 
Unity 4600
:
1.
If audio or video are missing, check at the front-panel monitor jacks. If okay on the front 
monitors, check the signal connections from the rear of the unit to the destination. If an 
audio is missing from the rear panel outputs and cannot be detected at the front-panel 
monitors, check that a valid audio stream is selected for that port and that the network 
provider has supplied non-quiet programming on that audio.
2.
If the ASI output is missing, check the signal connections from the rear of the unit to the 
destination. If okay, check with the network provider to verify what Program Mapping 
(Release 2 or later) may be in effect.
4.3  Alarms and Warnings
The alarm and warning system is intended to alert the local user of a present or impending 
loss of services. 
 below lists many (but not all) of the possible alarm and warning 
messages that the 
Unity 4600
 may display. For problems you cannot resolve on your own, 
please contact Wegener Customer Service (see Chapter 5), and be prepared to describe 
your signal setup, 
Unity 4600
 configuration, and any displayed alarm and warning 
messages.
Alarms
An alarm is asserted when the unit is unable (or presumed to be unable) to perform a 
required function or deliver required services.
Warnings
A warning is asserted when an alarm condition is imminent or to indicate other conditions 
requiring user attention.