(8) USB Monitor Control will be available when installing
"USB Monitor Control Software" into the computer.
The "USB Monitor Control Software" can be down-
loaded from Mitsubishi Internet Home Page:
http://www.mitsubishi-display.com/
You can confirm that Enumeration of Mitsubishi Monitor
Function is successfull with the following method.
Open “Device Manager” tab in “System” property
under “Control Panel”. Confirm that “HID-compliant
Device” and “USB Human Interface Device” are listed
in “Human Interface Device”. If you can’t confirm it, re-
enumerate “Mitsubishi Monitor Function” again by
following (a) or (b).
(a) Disconnect and connect the USB cable to the up-
stream port of the display monitor.
(b) Cycle power of  the display monitor off then on.
If  the mark       appears with “HID-Compliant Device”
and/or “USB Human Interface Device”, the enumera-
tion was unsuccessful.  Select “HID-Compliant Device
“and/or “USB Human Interface Device marked with
  mark and click “Remove” and “Refresh”.  After
that, the enumeration is automatically started.
Figure 12
Figure 13
N O T E
N O T E
The following should be observed in order to use the USB
function reliably:
Make sure the connection is made firmly and correctly.
Close all Windows program before changing the Up-
stream port or disconnecting USB cable.
Generic USB Hub