GE PT878GC Manual De Usuario

Descargar
Página de 308
3-21
April 2004
Installing DMP-1 Dampening Material with CFG-V 
Series Fixtures
1. Be sure the CFG-V clamping fixture is installed on the pipe 
with the transducers as described in the section Installing the 
V Series Clamping Fixture and Transducers
 on page 3-8. 
With a marker, mark scribe lines on the inside edges of the 
brackets onto the pipe. These lines indicate where to apply the 
material. (One 9.5-in. roll fits between the brackets.)
2. Remove the fixture and transducers.
3. Use a dry towel or rag and thoroughly dry the pipe.
4. Unroll the DMP-1 material and cut off a length equal to the  
circumference. Peel the paper backing off the cut portion. 
IMPORTANT: The DMP-1 material will only adhere to the pipe 
correctly if the pipe is completely dry. To adhere 
properly, the material must also be at a 
temperature above 50°F (10°C).
5. Before more atmospheric condensation can occur on the 
outside of the pipe, roll the DMP-1 dampening material once 
around the pipe, following the scribe marks that represent the 
inside edge of the fixture, as shown in Figure 3-23 below. 
Figure 3-23:  DMP-1 Dampening Material 
Wrapped Around Pipe
6. Reinstall the fixture, and make sure the spacing is set 
correctly. Loosely mount the transducers on top of the 
dampening material, using the correct spacing.