Magnum 6K25 Managed Fiber Switch            Installation and User Guide (04/06) 
 
21 
www  GarrettCom  com
.
.
 
3.0  
Installation 
Before installing the equipment, it is necessary to take the 
following precautions: 
1.) 
If the equipment is mounted in an enclosed or multiple rack 
assembly, the environmental temperature around the equipment 
must be less than or equal to 50
0
C. 
2.) 
If the equipment is mounted in an enclosed or multiple rack 
assembly, adequate airflow must be maintained for proper and 
safe operation. 
3.) 
If the equipment is mounted in an enclosed or multiple rack 
system, placement of the equipment must not overload or load 
unevenly the rack system. 
4.) 
If the equipment is mounted in an enclosed or multiple rack 
assembly, verify the equipment’s power requirements to prevent 
overloading of the building/s electrical circuits. 
5.)  
If the equipment is mounted in an enclosed or multiple rack 
assembly verify that the equipment has a reliable and 
uncompromised earthing path.
 
6.)  
24vdc, -48vdc, and 125vdc must be installed in restricted 
access locations.
 
7.)  
CB-Circuit breakers of 10Amps should be shown on top of the 
Rack.
 
 
 
 
This section describes installation of the Magnum 6K25 Switches, as well as 
connection of the various Ethernet media types. 
 
3.1 
Locating Magnum 6K25 Switches 
 
The location of a Magnum 6K25 Switch is dependent on the physical layout of 
the network.  Typically the Switch is placed in a central wiring location where groups of 
network devices need to be connected in order to communicate with each other. These 
Switches are typically rack mounted in a wiring closet see Section 3.3.2 below), but 
because they have rubber feet they can also be installed on a shelf or table top unit. The 
compact size allows it to be easily placed in an office or lab area, and it can also be either 
shelf of wall-mounted (see Section 3.3.1 below).  
 
Locate an AC receptacle that is within six feet 
(2 meters) of the intended Magnum 6K25 site.  The 
rugged metal case of the Magnum 6K25 will normally 
protect it from accidental damage in a lab or workplace 
setting.  Maintain an open view of the front to visually 
monitor the status LEDs.  Keep an open area around the 
unit so that cooling can occur from the small fan on the 
left side, while the unit is in operation. See figure below. 
                                
Figure 3.1:  Location of the Magnum 6K25’s cooling fans