Ultra Start 2500 Manual De Usuario

Descargar
Página de 16
Installation Guide
2500  Wiring Diagram
         
Page 3
Page 5
Page 6-7
Pre-Installation
Page 4
Components 
Recommended Pre-Installation Procedures
Recommended Install procedures            
              
Wire Connectors
6 Pin Connector
14 Pin Connector
3 Pin Red Connector
4 Pin Blue Connector 
Jumper Selections
Installation
Basic Installation - Quick start
Plugging In The Module
Auto Tach Learn
Shock Sensor Programming
Programming
Page  7-11
Program Overview & System Reset
Program Menu 1 (User Settings)
Program Menu 2 (Alarm Settings)
Program Menu 3 (Starter Settings)
Program Menu 4 (Tach Settings)
Other Features And Operations
Page 12
Reservation Mode
Transmitter Programming
Battery Replacement
Service mode
Remote Service Mode
Warranty
System Operation
Page 14-15       
Relay Diagrams
Page 16
TABLE OF CONTENTS
If the remote starter has a failed start attempt or if a safety input is activated the Diagnostic Memory will 
store up to four shutdowns in memory. This information can then be accessed to determine the source of 
the shutdown. 
To Enter Diagnostic Mode:
Step 1 -  Turn the ignition on wait two seconds then turn off. Press the Program Button and release.
Step 2 -  The system will respond with three park light flashes and the siren will chirp the
               same number of times as the events in memory. ( Maximum four events, four chirps)
NOTE: If the siren does not chirp, there are no events in memory. 
Step 3 -  Press the Program Button  once to view  the last shut down code. The siren will chirp  once to  
               confirm code one. 
Step 4 -  The LED’s on the antenna will flash a code corresponding to a shut down trigger. Press the      
               Program Button again to check the second code. The siren will chirp twice to confirm code two.
Step 5 -  To  Clear Diagnostic Memory. While in Diagnostic Mode press and hold the Program Button for  
               five seconds. The park lights will flash and the siren will chirp once.
NOTE:  Once diagnostic memory has 4 improper shutdown events in memory, the system will not 
record any further shutdown events until the system memory has been cleared.
(If the siren does not chirp, there are no codes in memory). 
PARK LIGHTS
STATUS LED
DIAGNOSTIC CODE
3 Flashes
Series of 3 Flashes
Door Opened “M” Models
4 Slow Flashes
Series of 4 Flashes
Not in Reservation Mode “M” units
5 Flashes
Series of 5 Flashes
Hood Pin Grounded (Open)
6 Flashes
Series of 6 Flashes
Brake Pedal Shutdown
7 Flashes
Series of 7 Flashes
Tach Lock-Out
8 Flashes
Series of 8 Flashes
3 Start Attempts with no start
DIAGNOSTICS
2
1
3
5
2
4
6
2
1
4
3
6
5
7
8
10
9
12
11
14
13
10
12
11
13