Connect Tech titan-cpci Manual De Usuario

Descargar
Página de 34
Titan/cPCI User’s Manual, Connect Tech Inc. 
 
Revision 1.01  
 
11 
 
 Multi-drop Slave Mode 
In this mode the TxD line driver is enabled only when data is transmitted and RxD is enabled all 
the time.  This mode is typically used in multi-drop "4 wire" connections.  Please refer to 
 for the jumper settings associated with this function. 
 
Line Termination 
You can terminate and bias TxD +/-, RxD +/-, RTS +/-, and CTS +/- on the individual 
RS-422/485 ports through jumper selectable 150 
Ω fixed resistors.  Please refer to 
 for the jumper settings associated with this function. 
 
 
Software Installation 
Introduction 
Titan/cPCI boards are standard multi-port serial adapters that utilize 16C950 UARTs.  In many 
cases, users have software that will interface directly to the Titan/cPCI boards.  Many operating 
systems come with handlers to control access to multiple 8250 style UARTs.  Titan/cPCI 
adapters currently ship with device drivers for the following operating systems: 
 
ƒ  QNX 4 
ƒ  QNX 6 
ƒ  Windows NT 
ƒ   Linux 
 
 
Before installing the Titan/cPCI software device driver, verify and note jumper settings 
described in 
for: 
 
„
  Jumper block JA – Full duplex, half duplex and multi-drop slave control 
„
  Jumper block JB – RS-232, RS-485/422 select 
„
  Jumper blocks JC, JD, JE and JF – line bias/termination. 
If you require further information please contact Connect Tech Technical Support. 
 
Technical Tips: 
Your Titan/cPCI adapter may ship with diskettes that include 
howto.txt
 
or 
readme.txt
 files.  Please examine these files for technical tips or 
release notes concerning installation and configuration of various 
device drivers and software utilities. 
 
If you did not receive a driver diskette for your operating system or you 
require additional information, please go to the 
of the 
 on the Connect Tech website for product manuals, 
installation guides, diagnostic utilities and device driver software.