Appendix C: Factory Settings 
Titan/cPCI Adapters 
 
Function 
Factory Setting 
Electrical Interface  Jumper block JB is set for all ports 
RS-422/485 - all positions not jumpered 
Half Duplex  
(2 wire) 
Jumper block JA is set for all ports 
running in full duplex or multi-drop slave 
mode - all positions not jumpered  
Termination 
Jumper blocks JC, JD, JE and JF are set 
for all ports not terminated or biased - all 
positions not jumpered  
Please see 
 for the locations of these jumper blocks. 
 
Titan/cPCI Rear I/O adapters 
 
Function 
Factory Setting 
Electrical Interface  Jumper blocks JA, JB, JC, JD are set for 
all ports RS-422/485 – positions 1 not 
jumpered 
Half Duplex  
(2 wire) 
Jumper blocks JA, JB, JC, JD are set for 
all ports running in full duplex or multi-
drop slave mode - positions 2 not 
jumpered  
Termination 
Jumper blocks J4 is set for no terminated 
or biased – positions 3, 4, 5, 6, 7, and 8 
not jumpered  
Please see 
for the locations of these jumper blocks.