Connect Tech titan-cpci Manual De Usuario

Descargar
Página de 34
Titan/cPCI User’s Manual, Connect Tech Inc. 
20  
Revision 
1.01 
 
Full Duplex Mode  (4 wire) 
By not installing pins on jumper block JA and by using features in our driver software, you can 
run the individual RS-422/485 ports in full duplex mode. This mode is typically used in point to 
point RS-422/485 situations much like RS-232.  In this mode, TxD & RxD are active all the 
time.  
 shows the location of jumper block JA. 
 
Half Duplex RS-422/485 (2 wire) 
By installing pins on jumper block JA and using features in our driver software, you can run the 
individual RS-422/485 ports in half duplex mode.  In this mode your Titan/cPCI adapter controls 
the transmitter and receiver circuits.  DTR is turned on prior to and during transmission to cause 
the transmit driver to enable and the receiver to disable.  DTR is turned off when not 
transmitting to cause the transmit driver to disable (tri-stated) and the receiver to enable. The 
16C950 UARTs on the Titan/cPCI adapter are responsible for timing the DTR toggle.  
 
Multi-drop Slave Mode (4 wire) 
By not installing jumpers on jumper block JA and by using features in our driver software, you 
can run the individual RS-422/485 ports in multi-drop slave mode.  In this mode the TxD line 
driver is enabled only when data is transmitted and RxD is enabled all the time.  This mode is 
typically used in multi-drop 4-wire connections. 
 
Example 
The example below shows the settings on JA where RS-422/485 
ports 1 and 2 are set for full duplex or multi-drop slave mode, 
port 3 is set for half duplex and port 4 is not set since port 4 is 
set for RS-232 on jumper block JB.
 
 
JA 
Jumper Legend 
Jumpers on = ½ duplex 
enabled 
Port 1
Port 2
Port 3
Port 4
4 port models 
JA0 
JA1 
JA2 
JA3 
 
Technical Note: 
Full duplex, multi-drop slave and half duplex modes apply to 
RS-422/485 ports only.  Please ensure that the port is set for 
RS-422/485 on jumper block JB.