F. Diagnostic Charts
1. No Ice Production
Problem
Possible Cause
Remedy
[1] The icemaker will not 
start. 
a) Power Supply
1. Off, blown fuse, or 
tripped breaker.
1. Turn on, replace, or reset.
. Loose connection.
. Tighten.
3. Bad contacts.
3. Check for continuity and 
replace.
4. Not within 
specifications.
4. Refer to nameplate and 
correct.
b) Water Supply
1. Water supply off or 
pressure too low.
1. Check and get 
recommended pressure.
c) Power Switch 
(Control Box)
1. "OFF" position.
1. Move to "ON" position.
. Bad contacts.
. Check for continuity and 
replace.
d) Circuit Protect Relay
1. Power supply not 
within specifications.
1. Refer to nameplate and 
correct or re-wire.
. Bad Contacts.
. Check for continuity and 
replace.
e) Transformer
1. Coil winding opened.
1. Replace.
f)  Fuse (Control Box)
1. Blown.
1. Check for short circuit and 
replace.
g) Infrared Sensor
1. No power or defective. 1. See "IV.D. Bin Control 
Check."
h) Mechanical Bin 
Control (Backup Bin 
Control Safety)
1. Tripped with bin filled 
with ice. (9-beep 
alarm)
1. Remove ice.
. Mechanical bin control 
stuck open.
. See "IV.D. Bin Control 
Check."
3. Actuator paddle does 
not move freely.
3. Clean shaft and its 
corresponding holes 
or replace damaged 
components.
i)  High Pressure Switch 1. Bad Contacts.
1. Check for continuity and 
replace.
. Dirty air filter or 
condenser.
. Clean.
3. Ambient or condenser 
water temperature too 
warm.
3. Reduce temperature.
4. Refrigerant 
overcharged.
4. Recharge.
5. Fan not operating 
(except water-cooled 
model).
5. See chart "3.[.]a) Fan 
Motor"
6. Refrigerant line or 
component restricted.
6. Remove the restriction or 
component and replace the 