3. Other
Problem
Possible Cause
Remedy
[1] Icemaker will not stop 
when bin is filled with 
ice.
a)Bin Control
1. Erratic or defective.
1. See "IV.D. Bin Control 
Check."
[] Abnormal noise
a)Fan Motor (except 
water-cooled model)
1. Bearing worn out.
1. Replace.
. Fan blade deformed.
. Replace fan blade.
3. Fan blade does not 
move freely.
3. Replace.
b)Compressor 
1. Bearings worn out, or 
cylinder valve broken.
1. Replace.
. Mounting pad out of 
position.
. Reinstall.
c) Refrigerant Lines
1. Rub or touch lines or 
other surfaces.
1. Reposition.
d)Auger
1. Bearings or auger 
worn out.
1. Replace bearings or 
auger. See "V.D.1. Upper 
Bearing Wear Check."
e)Gear Motor 
1. Bearing or gear worn 
out / damaged.
1. Replace.
f) Evaporator
1. Scale on inside wall 
of evaporator freezing 
cylinder. 
1. Use "SCALE AWAY" 
solution to clean 
periodically. If the water 
is found hard by testing, 
install a softener.
. Low refrigerant 
pressures. 
. Check charge, check for 
possible leak, repair,
re-charge.
3. Expansion valve bad. 3. Replace.
4. Evaporator bad.
4. Replace.
[3] Overflow from 
reservoir (water does 
not stop).
a)Water Supply
1. Water pressure too 
high.
1. Install a pressure reducing 
valve.
b)Inlet Water Valve
1. Diaphragm does not 
close.
1. Clean or replace.
c) Float Switch
1. Bad contacts.
1. Check for continuity and 
replace.
[4] Gear motor protector 
operates frequently or 
fuse blows frequently.
a)Power Supply
1. Not within 
specifications.
1. Refer to nameplate and 
correct.
b)Evaporator Assembly
1. Gear motor bearings 
or auger bearings 
worn out.
1. Replace bearings or 
auger. See "V.D.1. Upper 
Bearing Wear Check."
c) Bin Control
1. Defective.
1. See "IV.D. Bin Control 
Check."
. Actuator does not 
move freely.
. Clean shaft and its 
corresponding holes or 
replace bin control.
d)Control Board
1. Erratic operation of 
gear motor relay.
1. See "IV.B. Diagnostic 
Procedure."