Hoshizaki FD-1001MRH(-C) Manual De Usuario

Descargar
Página de 103
9
Note: We reserve the right to make changes in specifications and design without prior 
notice.
2. FD-1001MAH-C (air-cooled)
AC SUPPLY VOLTAGE
208-230/60/1 (3 wire with neutral for 115V) 
COMPRESSOR
240 V
4.2 RLA
34 LRA
GEAR MOTOR
120 V
3    FLA
1/4 HP
FAN MOTOR
115 V
0.85FLA
1/15 HP
OTHER
120 V
0.03A
MAXIMUM FUSE SIZE
15 A
MAX. HACR BREAKER (USA ONLY)
15 A
MAX. CIRC. BREAKER (CANADA ONLY)
15 A
MINIMUM CIRCUIT AMPACITY
15 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
    lbs./day ( kg/day )
70
*940 (427)
890 (405)
855 (389)
Reference without *marks
80
820 (373)
790 (358)
755 (344)
90
725 (330)
*695 (317)
670 (304)
100
640 (292)
615 (280)
*580 (265)
SHAPE OF ICE
Cubelet
ICE QUALITY
Approx.  80%, Ice  (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY
N/A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
    ELECTRIC    W  (kWH/100 lbs.)
1390 (4.8)
1320 (3.4)
    POTABLE WATER
86 (12)
113 (12)
             gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)
22" x 24" x 25-15/16"  (560 x 610 x 658mm)
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear) 
WEIGHT
Net 176 lbs. ( 80 kg ), Shipping 205 lbs. ( 93 kg )
CONNECTIONS - ELECTRIC
Permanent - Connection
                      - WATER SUPPLY
Inlet 1/2" FPT
                      - DRAIN
Outlet   3/4" FPT
ICE MAKING SYSTEM
Auger type
HARVESTING SYSTEM
Direct Driven Auger ( 1/4 HP Gear Motor )
ICE MAKING WATER CONTROL
Float Switch
COOLING WATER CONTROL
N/A
BIN CONTROL SYSTEM (PRIMARY)
Photoelectric Sensor
BIN CONTROL SYSTEM (SECONDARY)
Mechanical Bin Control (Proximity Sw.)
COMPRESSOR
Hermetic,     Model RS70-C1E-PFV
CONDENSER
Air-cooled, Fin and tube type
EVAPORATOR
Copper Tube on Cylinder
REFRIGERANT CONTROL
Thermostatic Expansion Valve
REFRIGERANT CHARGE
R-404A,
1 lb.12oz.
(800g)
DESIGN PRESSURE
High 427 PSIG,  Low 230 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-off Relay
COMPRESSOR PROTECTION
Internal Protector
GEAR MOTOR PROTECTION
Fuse (3A)
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch and Timer
ACCESSORIES -SUPPLIED
Spare Fuse
                          -REQUIRED
Ice Storage Bin
OPERATING CONDITIONS
VOLTAGE RANGE
187-253 V
AMBIENT TEMP.
45-100° F
WATER SUPPLY TEMP.
45-90° F
WATER SUPPLY PRESSURE
10-113 PSIG
ENG F-013.0.1196