fetco cbs-2052e Manual De Usuario
13
Error Codes
Code
Description
Possible Cause
Corrective Action
How to Clear Error
Codes
001 Internal
Error
System had to reload
default settings.
default settings.
Control board failure.
Clear error.
Re-program the brewer to
the desired specifications. If
error occurs again, replace
control board.
Re-program the brewer to
the desired specifications. If
error occurs again, replace
control board.
Turn main power
switch off and on.
switch off and on.
050
Shorted temperature probe. Probe failure.
Replace probe.
Turn main power
switch off and on.
switch off and on.
051
Open temperature probe.
Bad probe connection,
or probe failure.
or probe failure.
Check all connections.
Replace probe if necessary.
Replace probe if necessary.
Turn main power
switch off and on.
switch off and on.
Brew basket sensor or
lock has failed.
lock has failed.
Repair or replace brew
basket sensor or lock.
basket sensor or lock.
Press the flashing
control panel power
switch to resume
operation.
control panel power
switch to resume
operation.
075
Brew basket lock or sensor
failure.
Basket was in place when
brew cycle started, but was
pulled out during the brew
cycle. If this error occurs,
the brew basket lock has
failed.
failure.
Basket was in place when
brew cycle started, but was
pulled out during the brew
cycle. If this error occurs,
the brew basket lock has
failed.
Magnet in brew basket
handle is missing or
loose.
handle is missing or
loose.
Remove brew basket
handle. Place magnet in
correct position.
handle. Place magnet in
correct position.
100
Initial Fill Error
Initial fill time was more
than 15 minutes.
Initial fill time was more
than 15 minutes.
Water supply flow rate
is too low.
is too low.
Watch for short potting
during brew cycle.
Investigate cause of low flow
rate. (Clogged water filter,
etc.)
during brew cycle.
Investigate cause of low flow
rate. (Clogged water filter,
etc.)
Press the control
panel power switch.
panel power switch.
101
Error on refill
Tank did not refill within 3
minutes.
Tank did not refill within 3
minutes.
Water supply flow rate
is too low.
is too low.
Watch for short potting
during brew cycle.
Investigate cause of low flow
rate. (Clogged water filter,
etc.)
during brew cycle.
Investigate cause of low flow
rate. (Clogged water filter,
etc.)
Error message is
cleared
automatically at
end of brew cycle.
cleared
automatically at
end of brew cycle.
Possible leak in tank,
fitting, or valve.
fitting, or valve.
Check inside of machine for
leaks.
leaks.
102 Unwanted
Fill
When brewer is idle, the fill
valve was activated for
more than 30 seconds
during a 1 hour period.
valve was activated for
more than 30 seconds
during a 1 hour period.
Output on control
board has failed,
causing a dispense
valve to open.
board has failed,
causing a dispense
valve to open.
Replace control board.
Turn main power
switch off and on.
switch off and on.
200
Flat Line Temperature
(Water is boiling)
System is calling for heat,
but the temperature does
not rise at least 2
(Water is boiling)
System is calling for heat,
but the temperature does
not rise at least 2
°F within
10 minutes.
Triac is stuck closed,
bad output on control
board, or temperature
is set too high for
altitude.
bad output on control
board, or temperature
is set too high for
altitude.
Check triacs, check control
board output, or adjust
temperature for altitude.
board output, or adjust
temperature for altitude.
Turn main power
switch off and on.
switch off and on.
201 Heater
Open
System is calling for heat,
but the temperature does
not rise at least 2
but the temperature does
not rise at least 2
°F within
10 minutes. This error is
disabled during brewing
and while using the hot
water faucet.
disabled during brewing
and while using the hot
water faucet.
Heating element
failure.
failure.
Check and replace heating
elements if necessary.
elements if necessary.
Turn main power
switch off and on.
switch off and on.
202 Heater
Short
System is not calling for
heat, but temperature rises
more than 5
heat, but temperature rises
more than 5
°F.
Possible triac stuck
closed, or bad output
on control board.
closed, or bad output
on control board.
Check triac and control
board.
board.
Enter programming
mode, then exit
programming
mode.
mode, then exit
programming
mode.
255 Keypad
Error
A switch was pressed for
more than 45 seconds.
more than 45 seconds.
Switch was held in too
long, or switch is stuck
closed.
long, or switch is stuck
closed.
Clear error and try again. If
error occurs without switch
being pressed, replace input
board.
error occurs without switch
being pressed, replace input
board.
Turn main power
switch off and on.
switch off and on.