C7772A, F, G WALLPLATE TEMPERATURE SENSOR
Automation and Control Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN  55422
customer.honeywell.com
® U.S. Registered Trademark
© 2012 Honeywell International Inc.
68-0213—04   L.L.  Rev. 01-2012 
Printed in United States
CHECKOUT
The C7772 Wallplate Temperature Sensor is immediately 
operational after wiring connections are made. Use an 
accurate thermometer of ±1°F (0.5°C) to measure the 
temperature at the sensor location. To verify sensor accuracy, 
use an ohmmeter to measure the resistance across the 
sensor wires and use Table 2 to check the accuracy of the 
specific model.
Table 2. Typical Resistance of Sensor Models.
Typical Resistance (in ohms)
C7772A
C7772F
C7772G
At 41°F (5°C)
54,200
25,392
23,467
At 50°F (10°C)
41,758
19,901
18,789
At 59°F (15°C)
32,427
15,712
15,137
At 68°F (20°C)
25,370
12,493
12,268
At 77°F (25°C)
20,000
10,000
10,000
At 86°F (30°C)
15,856
8,057
8,196
At 95°F (35°C)
12,654
6,531
6,754