Furuno FS-5070 Manual De Usuario

Descargar
Página de 219
10. NBDP TRANSMITTING, RECEIVING 
 10-3
10.2  ARQ Mode Operation 
In ARQ operation, one station (information sending station) sends data to another block by 
block, then listens for the acknowledge signal between blocks from the information 
receiving station which requests either the next block or retransmission of the last block if 
there is error. The request may be repeated up to 32 times, until the complete block is 
received free of error. 
 
Establishing connection 
1.  Press the function key F3 to display the Operate menu. 
1: Call Station
3: File to Send
4: Cancel Sending
5: Scan (Start/Stop)
6: Manual Reception
7: Timer Operation
8: Manual Calling
9: Set Frequency
Operate
2: Macro Operation
 
2. Press the 1 key to choose Call Station. 
Caps-Eng
Station Name    :  CHOUSHI-8M
Frequency (T/R) :   8765.00 / 8965.00(kHz)  Comm Mode :AQW
Comm Status     :  
Connect
 
Send
 
Lock
 Error  Mark  Space
Sending Volume  :  100(%)   ARQ Error : 0   ARQ Time : 0(sec)
2002-01-15 14:41:09 UTC
Call Station
Station List
ABC-4M
ABC-6M
ABC-12M
ABC-8M
FURUNO
Station Setup
Station  : ABC-4M
ID Code  : 45678
Mode     : ARQ FEC
CH/Table : Channel Scantable
Num/Table:
1:File 2:Edit 
3:Operate
 4:Window 5:Station 6:System 7:WRU 8:HR 9:Over 10:Break
 
Call Station menu 
3.  Choose a station. (Station must be registered for use in the ARQ mode). Press the 
Enter key. The message “Calling Station” appears. If the message shown below 
appears, check both the power of the radiotelephone and the connections between the 
radiotelephone and the NBDP Terminal Unit. 
“Station calling suspended. Check interconnections between the terminal and main units. 
Press any key to escape.” 
4.  When an acknowledge signal is detected, “Connect” appears in reverse video on the 
communication status display.