5. Now you are ready to connect the copper tubing. Use 
¹⁄₄" 
(6.35 mm) OD soft copper tubing for the cold water supply.
Ensure that you have the proper length needed for the 
job. Be sure both ends of the copper tubing are cut 
square.
Slip compression sleeve and compression nut on copper 
tubing as shown. Insert end of tubing into outlet end 
squarely as far as it will go. Screw compression nut onto 
outlet end with adjustable wrench. Do not overtighten.
6. Place the free end of the tubing into a container or sink, and 
turn on main water supply and flush out tubing until water is 
clear. Turn off shutoff valve on the water pipe.
NOTE: Always drain the water line before making the final 
connection to the inlet of the water valve to prevent possible 
water valve malfunction.
7. Bend the copper tubing to meet the water line inlet which is 
located on the back of the ice maker cabinet as shown. 
REAR VIEW
8. Thread the nut onto the coupling on the end of the copper 
tubing. Tighten the nut by hand. Then tighten it with a wrench 
two more turns. Do not overtighten.
NOTE: To prevent rattling, be sure the copper tubing does 
not touch the cabinet’s side wall or other parts inside the 
cabinet.
9. Turn shutoff valve ON.
10. Check for leaks. Tighten any connections (including 
connections at the valve) or nuts that leak.
Drain Connection
Gravity Drain System
Connect the ice maker drain to your drain in accordance with all 
state and local codes and ordinances. If the ice maker is 
provided with a gravity drain system, follow these guidelines 
when installing drain lines. This will prevent water from flowing 
back into the ice maker storage bin and potentially flowing onto 
the floor causing water damage.
Drain lines must have a minimum of 
⁵⁄₈" (15.88 mm) inside 
diameter.
Drain lines must have a 1" drop per 48" (2.54 cm drop per 
122 cm) of run or 
¹⁄₄" drop per 12" (6.35 mm per 30.48 cm) of 
run and must not have low points where water can settle.
The floor drains must be large enough to accommodate 
drainage from all drains.
The ideal installation has a standpipe with a 1
¹⁄₂" (3.81 cm) to 
2" (5.08 cm) PVC drain reducer installed directly below the 
outlet of the drain tube as shown. You must maintain a 
1" (2.54 cm) air gap between the drain hose and the 
standpipe.
It may be desirable to insulate the drain line thoroughly up to 
the drain inlet.
SIDE VIEW 
Drain Pump System (on some models)
Connect the ice maker drain to your drain in accordance with the 
International Plumbing Code and any local codes and 
ordinances.
NOTE: If the drain hose becomes twisted and water cannot 
drain, your ice maker will not work.
A. Cold water pipe
B. Pipe clamp
C. Copper tubing
D. Coupling (purchased) 
E. Compression nut
F. Compression sleeve
G. Shutoff valve
H. Packing nut
A. Drain hose (drain pump models only)
B. Vent hose (drain pump models only)
C. Water supply line
A. Line to ice maker
B. Nut (purchased)
C. Ferrule (purchased)
D. Coupling (purchased)
E. Ferrule (purchased)
F. Nut (purchased)
A
B
C
D
E
F
G
H
A
C
B
D
E
F
A
B
C
A. Drain hose
B. 1" (2.54 cm) air gap
C. PVC drain reducer
D. Center of drain should be 23" (58.4 cm) from front of door, 
with or without the 
³⁄₄" (1.91 cm) panel on the door. The 
drain should also be centered from left to right (8
³⁄₁₆
[22.37 cm] from either side of the ice maker). 
3
⁵⁄₈
"
(9.2 cm)
23"
(58.4 cm)
2" - 1
¹⁄₂
"
(5 cm - 3.8 cm)
1" (2.54 cm)
A