System Charge for Various Matched Systems
Outdoor Unit
YCJD18
S41S1(H)(E)
YCJD24
S41S1(H)(E)
YCJD30
S41S1(H)(E)
YCJD36
S41S1(H)(E)
YCJD42
S41S2(H)(E)
YCJD48
S41S1(H)(E)
YCJD60
S41S1(E)
Required Orifice or TXV
1,2
0.048/4F1
0.055/4F1
0.061/4F1
0.065/4G1
0.073/4G1
0.073/4H1
0.087/4J1
Indoor Unit
3,4,5
Additional Charge, oz.
AHE18B
0
–
–
–
–
–
–
AHE24B
–
4
–
–
–
–
–
AHE30B
–
4
0
–
–
–
–
AHE36C
–
4
2
0
–
–
–
AHE42D
–
–
–
8
10
–
–
AHE48D
–
–
–
–
9
0
–
AHE60D
–
–
–
–
14
–
4
AHP18
0
–
–
–
–
–
–
AHP30
–
4
0
–
–
–
–
AHP36
–
–
2
0
–
–
–
AHP42
–
–
–
0
0
–
–
AHP48
–
–
–
–
10
0
–
AHP60
–
–
–
–
10
0
0
AHR18B
0
–
–
–
–
–
–
AHR24B
–
4
–
–
–
–
–
AHR30B
–
–
0
–
–
–
–
AHR36B
–
–
2
0
–
–
–
AHR42C
–
–
–
8
10
–
–
AHR48D
–
–
–
–
9
0
–
AHR60D
–
–
–
–
15
–
4
AHX18
0
–
–
–
–
–
–
AHX30
–
4
0
–
–
–
–
AHX36
–
4
2
0
–
–
–
AHX42
–
–
–
8
10
–
–
AHX48
–
–
–
–
9
0
–
AHX60
–
–
–
–
15
–
4
AV*24
TXV + 0
–
–
–
–
–
–
AV*36
–
4
2
0
–
–
–
AV*48
–
–
–
–
TXV + 10
0
–
AV*60
–
–
–
–
TXV + 10
0
0
F4FP024
0
–
–
–
–
–
–
F4FP036
–
0
–
–
–
–
–
F4FP040
–
–
0
–
–
–
–
F4FV060
–
–
–
–
–
0
0
F5FP048
–
–
–
8
–
4
–
F5FP060
–
–
–
–
–
0
0
F6FP018
0
–
–
–
–
–
–
F6FP030
–
4
0
–
–
–
–
F6FP036
–
4
0
–
–
–
–
F6FP042
–
–
–
8
4
–
–
F6FP048
–
–
–
–
TXV + 9
0
–
F6FP060
–
–
–
–
15
–
4
FC/MC/PC18
0
–
–
–
–
–
–
FC/MC/PC32
–
4
0
–
–
–
–
FC/MC/PC35
–
4
0
–
–
–
–
FC/MC/PC36
–
0
–
–
–
–
–
FC/MC/PC37
–
4
2
0
–
–
–
For Notes See Page 4.