Unibrain 511 Manual De Usuario

Descargar
Página de 82
Unibrain Fire-i 501/511/601/701/702/810 Operation Manual 
 
Page 57 
 
 
 
4.9.3.  SIO (RS232) special Commands   
SIO(RS232) special commands are non IIDC compliant and are specific mode for the Fire- cameras.   
0xF2F10018 
Auto-Sync Mode control register 
Bit 31 : auto sync enable 
Bit 30 : SIO enable mode (0 : custom mode, 1 : IIDC v1.31) 
Bit 27 : auto sync complete (read only. 1: ready, 0: not yet auto-sync)   
Read/Write 
 
Before using these commands serial communication parameters must be set at Serial_Mode_Reg (F2F22000h) 
Baud Rate 
Stop Bit 
Parity 
Flow Control 
57600 bps(default) 
1 bit 
None 
Non 
 
Command format:    [STX] [Command] [Data] [ETX] 
[STX]   
:  Command start character : ‘S’ 
Command]   :  Command length is 2byte. See next page command table. 
[Data]   
:  Data length is varied with each command. Data format is hexadecimal: ‘0’~’9’, ‘A’~’F’. 
[ETX]   
:   Command end character : ‘Z’   
Return value 
G’   
:  Command complete acknowledge. 
Gdd..d”  :  “dd..d”  is return data and hexadecimal character.   
U’  
:  Undefined command.  
Valid Character: ‘0’~’9’, ‘A’~’F’, ‘S’,’Z’ Invalid character is received is discarded.   
Example:  Gain setting command with 0x200 value 
All of “SA0200Z”,  “S A0 200 Z”,  “SA0 200Z”,  “S A0200 Z”, and “SKA0V200Z” are parsed to 
SA0200Z”.