Zebra Technologies R110XiTM Manual De Usuario

Descargar
Página de 184
74
R110Xi/R170Xi User Guide
12/23/04 23063L-003 Rev. 2
RFID Guidelines
Creating Basic RFID Label Formats
RFID Label Format 5—Write Tag, Read Tag, and Print Data on Label
Programmed to Transponder
306461746100000000000000
Read from Transponder
306461746100000000000000
Resulting Label
Front Panel Display (toggles between these two)
Line 
Number
Type This ZPL Code
Function of ZPL Code
1
^XA
Indicates start of label format.
2
^RS4
Sets tag type to EPC Class 1 96-bit.
3
^FO60,60
^A0N,40
^FN7
^FS
When the label prints, the data read from the tag at 
field variable 7 (
^FN7
) will be printed at location 
60,60.
4
^RFW,A
^FD0data
^FS
W,A = write ASCII
Writes “0data” into the block padded with 8 bytes of 
zeroes to make the data 12 bytes. The data written is: 
306461746100000000000000 (“0data” in ASCII)
5
^FN7
^RFR,A
^FS
R,A = read ASCII
Reads the tag data into field variable 7 (
^FN7
). After 
this occurs, any fields in this label format that have 
^FN7
 will be replaced with this read data.
6
^XZ
Indicates end of label format.
0data
 RFID TAG DATA
 3064617461000000
 RFID TAG DATA
 00000000