blue-seal g1100 Manual De Usuario

Descargar
Página de 54
-35- 
Revision 4/F3576 
© Moffat Ltd, December 2004 
Primary air shutter 
6.4  ADJUSTMENT / CALIBRATION 
6.4.2 DOOR CHAIN 
1)  Remove the bottom lintel (refer 6.2.5). 
2)  Loosen the two locknuts on each of the 
turnbuckles. 
1)  Loosen the ball catch locknut by one turn. 
2)  Use the adjusting tool provided with the 
oven to rotate the ball catch clockwise or 
anti-clockwise, moving it into and out of 
the door respectively.   
3)  Tighten the locknut to secure the new  
adjustment. 
Figure 6.4.2 
Turnbuckle Locknuts 
6.4.3  DOOR BALL CATCH 
3)  Adjust the turnbuckles such that the right 
hand door closes slightly ahead of the left 
hand door. 
 
To make the left hand door close earlier, 
tighten  the  left  hand  turnbuckle,  and 
loosen the right hand turnbuckle. 
 
To make the right hand door close earlier, 
tighten  the  right  hand  turnbuckle,  and 
loosen the left hand turnbuckle. 
4)  Tighten the locknuts. 
5)  Replace bottom lintel. 
1)  Gain access to the oven burners (refer 
6.2.6). 
2)  With  the  main  burners  on,  adjust  the  
primary air shutters at the front of each 
burner until optimum flame condition is 
established.   
NOTE:  Ideally flame should be blue/green in 
colour, exhibit no yellow tipping and no 
lifting off burner ports. 
6.4.4 BURNER AERATION 
Figure 6.4.4 
Figure 6.4.3 
Ball 
catch 
Figure 6.4.1 
6.4.1  GAS PRESSURE 
Units manufactured from S/N 275353. 
NOTE:
  The operating pressures should be 
adjusted to achieve the following required 
settings on both gas valves. 
 
  Natural Gas   
0.90 kPa (3.6.” w.c) 
 
  LP / Propane Gas  2.50 kPa (10.0” w.c) 
1) Remove  right  hand  side  panel  (refer 
6.2.4).   
2)  Unscrew the pressure test point screw at 
the bottom of the gas valve and connect 
pressure meter. 
3) Unscrew  the  regulator  screw  cap  to  
access  the  regulator  adjustment screw.  
With the burners on, adjust the regulator 
spring setting until the correct operating 
pressure  is  obtained.  This  regulator  is  
adjustable for Natural and LPG/Propane 
gas's operating pressures. 
NOTE:  Always set gas pressure with burners 
on.  Turning the regulator screw clockwise 
increases the gas pressure. 
4)  Refit the slotted caps, disconnect pressure 
meters and refit screws, refit side panel. 
Pressure 
test point  
Regulator 
screw