Chapter 3     Hardware Overview
AT-MIO/AI E Series User Manual
3-18
 National Instruments Corporation
In high-hysteresis analog triggering mode, the  trigger is generated 
when the signal value is greater than highValue, with the 
hysteresis specified by lowValue.
Figure 3-12.  High-Hysteresis Analog Triggering Mode
In low-hysteresis analog triggering mode, the trigger is generated 
when the signal value is less than lowValue, with the hysteresis 
specified by highValue.
Figure 3-13.  Low-Hysteresis Analog Triggering Mode
The analog trigger circuit generates an internal digital trigger based 
on the analog input signal and the user-defined trigger levels.  This 
digital trigger can be used by any of the timing sections of the 
DAQ-STC, including the analog input, analog output, and 
general-purpose counter/timer sections.  For example, the analog 
input section can be configured to acquire n scans after the analog 
input signal crosses a specific threshold.  As another example, the 
analog output section can be configured to update its outputs 
whenever the analog input signal crosses a specific threshold.
highValue
Trigger
lowValue
highValue
Trigger
lowValue