National Instruments pxi terminal block ni tb-2708 Manual De Usuario

Descargar
Página de 12
© National Instruments Corporation
9
NI TB-2708 Installation Guide
Specifications
This section lists the specifications of the TB-2708. These specifications 
are typical at 25 °C unless otherwise specified.
Input/Output
Refer to the documentation for your PXI-6115/6120 S Series device to 
determine the input/output specifications for your application.
Caution
Do not apply an input voltage greater than 42 V
pk
/60 VDC to the TB-2708. Input 
voltages greater than 42 V
pk
/60 VDC can damage the TB-2708 and any device connected 
to it, including the host computer. Overvoltage can also cause an electric shock hazard for 
the operator. National Instruments is not liable for damage or injury resulting from such 
misuse.
Physical
Dimensions
Height.............................................. 10.7 
× 8.6 × 2.0 cm
(4.2 
× 3.4 × 0.8 in.)
Weight............................................. 144.6 g (5.1 oz)
I/O connectors
68-position SCSI-II type ................. 1, female
SMB jacks....................................... 9
14-pin auxiliary connector .............. 1, Molex 14-pin microfit 
connector
Shock and Vibration
Operational shock .................................. 30 g peak, half-sine, 11 ms pulse 
(Tested in accordance with 
IEC-60068-2-27. Test profile 
developed in accordance with 
MIL-PRF-28800F.)
Random vibration
Operating ........................................ 5 to 500 Hz, 0.3 g
rms
Nonoperating .................................. 5 to 500 Hz, 2.4 g
rms
(Tested in accordance with 
IEC-60068-2-64. Nonoperating 
test profile exceeds 
the requirements of 
MIL-PRF-28800F, Class 3.)