Contec SPI-8452-LLVA Manual De Usuario

Descargar
Página de 123
6. RAID Controller 
 
 
 
64 
SPI-8451-LLVA, SPI-8452-LLVA, SPI-8451-LVA 
Viewing IDE Channel Information 
Left-clicking on a given Channel icon or # in the left pane, will show the Base IO addresses of the 
channel in the right pane (used for troubleshooting).
 
 
Viewing Drive Information   
Left-clicking on a given Drive icon or ID in the left pane, will show similar information categories as the 
Array Window Drive Information in the right pane.
 
 
 Status 
(also shown under the Array Window) can be Functional, Critical, or Offline.    The meanings 
are shown below. 
 Functional: Means the drive is working normally 
 Critical: A problem has been detected in the drive and the drive taken offline as part of a mirroring 
array. Mirrored arrays will continue to function without the drive.    Fix/replace the drive that has 
failed, and then restore data from a backup source. 
 Offline: Drives that are NOT identified as “bad” may be taken offline if part of a Striping or 
Spanning array containing a “bad” drive.    These drives do NOT need to be replaced, however.