Friedrich hazardgarg r-410a Manual De Usuario

Descargar
Página de 32
SPeCIfICATIONS AND PeRfORMANCe DATA
Cooling Performance Data
EVAPORATOR AIR 
TEMP. DEG. F
CONDENSER 
TEMPERATURE 
DEG. F
Discharge 
Temp
Suction 
Temp
Super 
Heat
Sub-
Cooling
OPERATING 
PRESSURES
ELECTRICAL RATINGS
R-410A REF.
Voltage
BREAKER 
FUSE
Discharge 
Air
Temp. Drop F.
Suction
Discharge Amps Cool Amps Heat Locked Rotor 
Amps
Charge in OZ.
60 Hertz 
Amps
SH15M30A
54
26
127
186
67
18
35
137
480
6.9
-
43
50
208 / 230
15
SH15M30A
54
26
185
124
68
15
38
137
485
9.1
-
43
42.7
208 / 230
15
7
Due to continuing engineering research and technology, specifications are subject to change without notice. Manufactured under U.S. Design Patent 
DES 368, 306 decorative front; Utility Patent 5, 622, 058. MAXIMUM outdoor ambient operating temperature is 130°F. MAXIMUM TEMPERATURE 
RATING FOR CLASS I, DIVISION 2, GROUPS A,B,C,D.
OPERATING TEMPERATURE CODE T3B
Specifications
Installation Information
Model
Cooling Capacity 
Electrical Characteristics (60 Hertz)
Energy 
Efficiency 
Ratio AHAM
Moisture
Removal 
Air Direction 
Controls
Room Side Air 
Circulation
(BTU/Hr.- AHAM)
Volts Rated
Amps AHAM
Watts
EER 
(Pints/ Hr.)
 CFM
SH15M30A
14500/14000
230/208
6.9/7.4
1495/1443
9.7/9.7
6.0
8-way
375
SH20M30A
19500/19000
230/208
9.1/10.0
2074/2021
9.4/9.4
4.0
8-way
375
Model
Dimensions 
(Inches)
Window
 
Width 
(Inches)
Thru-The-Wall
Finished Hole (Inches)
Circuit Rating 
Breaker or 
T - D Fuse
Weight
 
(Lbs.)
Height
Width
Depth 
Overall 
Depth J Box   
to Louvers
Minimum
Extension 
Into Room
Minimum 
Extension 
Outside
Min
.
Max
.
Height
Width
Max. Depth
Volts - Amps
Net
Shipping
SH15M30A
15 
15
/
16
25 
15
/
16
27 
3
/
8
6
1
/
16
16 
15
/
16
27 
7
/
8
42
16 
3
/
16
26 
3
/
16
6
250V - 15A
156
168
SH20M30A
17 
15
/
16
25 
15
/
16
27 
3
/
8
6
1
/
16
16 
15
/
16
27 
7
/
8
42
18 
3
/
16
26 
3
/
16
6
250V - 15A
160
174
(A)
Front
SIDE VIEW
(A)
Junction 
Box
Max.
Wall
Depth
STANDARD  ON ALL M ODEL S.
This advanced corrosion protection 
treatment protects the outdoor coil 
against deterioration and extends 
the life of the unit especially in harsh 
coastal environments.
All models use
environmentally 
friendly R-410A 
refrigerant.
R-410A
7