4.  Specifications 
 
Industrial Standards 
Complies with IEEE 802.3 10Base-T, IEEE 
802.3u 100Base-TX and ANSI/IEEE 802.3 
N-Way auto-negotiation standards; FCC 
Class A; CE mark. 
Interface 
Each unit has eight 10/100Mbps UTP ports 
(RJ-45). 
Port Speed/Mode Selection 
Auto-negotiation 
Link Distance 
100Base-TX: can support up to 100M of 
‘Category 5’ UTP cable to PC, Hub or 
another Switch. 
10Base-T: can support up to 100M of 
‘Category 3, 4, and 5’ UTP cable to PC, Hub 
or another Switch. 
LED Indicators  
LED indicators are provided for status 
monitoring. These include LEDs for system 
power, port speed, traffic activity and link. 
Dynamic memory sharing 
In/Out buffer 
128K bytes 
 
Forwarding Method 
Store-and-Forward. 
Number of MAC Addresses 
1K MAC Addresses 
Dynamic Addresses 
Learning / Filtering 
Yes. 
 
Environment Requirements 
Temperature: 
 
Humidity: 
 
Operating: 0
°C to 40°C 
Storage: -5
°C to 60°C 
Operating: 10% RH to 90% RH 
(non-condensing) 
Physical Dimensions 
151 x 92 x 25mm  (L x W x H) 
Safety 
UL, CSA, TUV/GS 
 
 
5.  Installation of PS2208B 
 
PS2208B can be installed on a flat surface (desktop) or mounted on a wall. 
Follow the steps below for proper installation. 
 
Desktop installation 
1.  Unpack the switch. 
2.  Choose a location near the devices to be connected and close to an 
electrical outlet. Preferably placed the switch on a desktop or any other 
clean, smooth, level and sturdy surface. 
3.  Ensure that there is enough clearance around the unit to allow attachment 
of network cables, power adapter and allow air circulation. 
4.  Connect the power adapter that is supplied in the package to the switch. 
The  POWER LED and PORT LED for each connected port should be 
lighted up. 
 
 
Wall installation 
1.  Measure the distance between the mounting holes at the bottom of the 
switch and mark the wall to match the location of the mounting holes on 
the switch. 
2.  Drill pilot holes at the two marked locations. 
3.  Fix two 5/16-inch diameters flat-head mounting screws into the wall, 
with the heads of the screws protruded 1/8 inch out from the wall. 
4.  Carefully set the switch over the screws in the wall; then slide the switch 
down onto the screws, pressing it slight to the wall. 
5.  Connect the power adapter that is supplied in the package to the switch. 
The  POWER LED and PORT LED for each connected port should be 
lighted up. 
 
 
This document may become superseded, in which case you may find its latest 
version at: 
http://www.compex.com.sg/prodspec.asp?f=Manual&s=1
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Disclaimer: Compex, Inc. provides this guide without warranty of any kind, either expressed or 
implied, including but not limited to the implied warranties of merchantability and fitness for a 
particular purpose. Compex, Inc. may make improvements and/or changes to the product and/or 
specifications of the product described in this guide, without prior notice. Compex, Inc will not be liable 
for any technical inaccuracies or typographical errors found in this guide. Changes are periodically 
made to the information contained herein and will be incorporated into later versions of the guide. The 
information contained is subject to change without prior notice. 
Trademark Information: Compex
®
,  ReadyLINK
®
 and MicroHub
®
 are registered trademarks of 
Compex, Inc.  Microsoft Windows and the Windows logo are the trademarks of Microsoft Corp. 
NetWare 
is the registered trademark of Novell Inc. All other brand and product names are trademarks 
or registered trademarks of their respective owners. 
Notice: Copyright 
©
 2004 by Compex, Inc. All rights reserved. Reproduction, adaptation, or translation 
without prior permission of Compex, Inc. is prohibited, except as allowed under the copyright laws. 
Manual Revision by Ong 
Manual Number: M-0311-V1.6C      Version 1.6, July 2004 
FCC NOTICE: This device has been tested and found to comply with the limits for a Class A digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This device generates, uses and can 
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may 
cause harmful interference to radio communications. However, there is no guarantee that interference 
will not occur in a particular installation. If this device does cause harmful interference to radio or 
television reception, the user is encouraged to try to correct the interference by one or more of the 
following measures: 
Reorient or relocate the receiving antenna. 
Connect the computer into an outlet on a 
circuit different from that to which the 
receiver is connected. 
• 
• 
 
Increase the separation between the 
computer and receiver. 
Consult the dealer or an experienced 
radio/TV technician for help. 
Caution: Any changes or modifications not expressly approved by the grantee of this device could void 
the user's authority to operate the equipment. 
FCC Compliance Statement: This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions: 
(1) 
(2) 
This device may not cause harmful interference, and 
This device must accept any interference received, including interference that may cause 
undesired operation. 
ICES 003 Statement 
This Class A digital apparatus complies with Canadian ICES-003 
DECLARATION OF CONFORMITY:
 Compex, Inc. declares that the product: 
Product Name: Compex Fast Ethernet Desktop Switch 
Model No.: PS2208B conforms to the following Product Standards: 
Radiated Emission Standards: EN55022A, FCC Part 15 Class A 
Conducted Emission Standards: EN60555Pt2 conducted emission; EN55022A conducted emission, 
LVD 60950 standard, FCC Part 15 Class A 
Immunity Standards: IEC 801-2; IEC 801-3; IEC 801-4 
Low Voltage Directive: EN 60 950:1992+A1: 1993+A2: 1993+A3; 1995+A4; 1996+A11: 1997. 
Therefore, this product is in conformity with the following regional standards: FCC Class A 
 
following the provisions of FCC Part 15 directive; CE Mark 
 following the provisions of the EC 
directive. 
Manufacturer’s Name: Compex, Inc. 
Address: 4051 E. La Palma, Unit A, 
Anaheim, CA 92807, USA 
European Contact & Technical Support 
ReadyLINK Networktechnology GmbH, 
Albert Einstein Stra
βe 34/M21, 
63322 Rödermark, Germany 
Fax: ++49 (60) 749-0668 
 
 
 
 
 
WARRANTY REGISTRATION CARD 
[M-0088-V2.3C] 
 
You can register via Internet at: 
http://www.cpx.com   or  http://www.compex.com.sg 
Or E-mail: support@compex.com.sg  with the following information: 
To activate the warranty, please complete this card and return to Compex within ninety (90) days of 
purchase date. 
Product:  
Purchase Date: 
Revision: 
Serial No: 
Name: Title: 
E-mail: 
Company: Dept: 
Address: City: 
Postal/Zip Code: 
State: 
Country: 
Phone:  (          ) 
Extn: 
Fax:  (          ) 
Computer in which this product is 
installed? 
Model: Serial 
No: 
! TCP/IP 
! IPX/ODI 
! XNS 
! OST 
! DLC 
! DECnet 
Network 
protocol (Check 
all that apply): 
! NDIS 
! SNA 
! NBP 
! Other: 
Novell NetWare:   ! 3.X   ! 4.X   ! 5.X 
SCO Unix: ! Openserver Ver:      
Microsoft Windows:   ! NT4.0     ! 95     ! 98      ! Win 2000 
Linux:   ! Red Hat Ver:            ! SUSe Ver:            ! Others:                Ver:       . 
Network 
Operating 
System (Check 
all that apply): 
Others NOS:                                                                                              Ver:        .    
! Desktop Publishing 
! Word Processing 
! Accounting 
! CAD/CAM 
! Spreadsheet 
! Database Management 
Applications used on 
network processing   
(Check all that apply): 
! E-mail 
! Other: 
! Work
! Friend 
! Internet 
! Dealer 
! Magazine 
! Exhibition 
How did you 
learn about 
Compex? 
! Other: 
 
Note: 
For purchases within U.S.A and Canada, please fax to Compex, Inc. at (714) 630-6521 
 
For purchases outside U.S.A and Canada, please fax to Compex Systems Pte Ltd at  (65) 6280-9947 
 
 
 
 
 
----
"
-----Cut along the dotted line-----
"
-----Cut along the dotted line-----
"
-----Cut along the dotted line-----
"
---- 
----
---
-C
ut
 a
lo
ng
 th
do
tt
ed
 li
ne
------
"
--
---
-C
ut
 a
lo
ng
 th
do
tt
ed
 li
ne
------
"
--
---
-C
ut
 a
lo
ng
 th
e d
ot
te
d l
in
e------
"
--
---
- C
ut
 a
lo
ng
 th
e d
ot
te
d l
in
e-----