CHECKING FOR PROPER VENTING 
After  completing  and  checking  electrical, 
gas and vent connections, follow the lighting 
instructions  and  allow  main  burner  to  run 
for approximately 5 minutes. Hold a lighted 
match or cigarette near the top edge of fire-
place opening and play it along entire length 
of  opening  (see  Figure  12).  Proper  venting 
should tend to draw the flame or smoke into 
the appliance. Improper venting or escaping 
of spillage of burned gas, is indicated when 
the match flickers or goes out. Smoke from a 
cigarette will also tend to disperse away from 
the appliance.
If appliance is found to be improperly vent-
ing,  shut  it  off  and  notify  your  installer  or  a 
qualified service agency to inspect the vent-
ing system.
VeNtING INstallatIoN
Continued
Check this area 
along entire top 
edge of fireplace 
opening. Smoke 
or flame should be 
drawn into appliance 
opening.
Figure 12 - Checking for Spillage
INstallatIoN
Figure 13 - Removing Front Refractory 
Access Panel
NOTICE:  This  appliance  is 
equipped  with  a  vent  safety
shutoff  switch  which  will  shut
down the appliance in the case
of  a  venting  problem.  Do  not
bypass the vent safety switch. If
the appliance should shut down,
contact a qualified installer, ser-
vice agency or your gas supplier 
to have the vent inspected before
operating.
WALL SWITCH INSTALLATION
The installation of a wall switch allows you to 
activate the gas control valve without normal 
household electricity since valve operates on 
millivolt current supplied by heat generated by 
the thermopile. To install wall switch:
1.  Remove front refractory access panel by 
lifting up and angling out of firebox open-
ing (see Figure 13).
2.  Use wire and connectors provided. Attach 
red  wire  to  terminal  marked  TH/TP  on 
control valve. Attach white wire to blade 
connector  on  open  end  of  safety  circuit 
wiring (see Wiring Diagram, page 22).
Note: If any of the original wire from unit con-
trol must be replaced, use the same type or a 
higher rated wire (25 ft. maximum length).
 WARNING:  Do  not  wire  re-
mote wall switch to main power
supply  (Standard  120v  house-
hold current).
3.  Locate wall switch in a convenient location.
4.  After  wire  connections  are  complete, 
replace refractory access panel.