Bunn CDS-3 Manual De Usuario

Descargar
Página de 34
23
SERVICE (cont.)
LAMP CORD ASSEMBLY
FIG. 17 LAMP CORD ASSY
P1891
Location:
The lamp cord assembly is located in the top of 
the dispenser.
Test Procedures:
1.  Disconnect the dispenser from the power source.
2.  Unplug the lamp cord assembly from lamp cord 
connector assembly.
3.  Check for continuity across the tip of the cord as-
sembly and the housing. Continuity must not be 
present when the lamp is removed.
If continuity is present as described, the cord assembly 
is operating properly.
If continuity is not present as described, replace the 
cord assembly.
Removal and Replacement:
1.  Disconnect  the  lamp  cord  assembly  from  the 
lamp cord connector assembly in the top of the 
dispenser.
2.  Open the dispenser door and remove the five screws 
securing the rear cover to the door.
3.  Disconnect the lamp cord assembly from the lamp 
holder/socket  assembly  and  set  the  rear  panel 
aside.
4.  Cut the terminals off of the lamp cord assembly.
5.  Remove  lamp  cord  assembly  from  the  door  as-
sembly and discard.
6.  Push new lamp cord wires through the holes on 
the top of the door assembly.
7.  Strip the wires from the new lamp cord approxi-
mately .281”.
8.  Using the two terminals supplied, crimp the new 
terminals to the lamp cord assembly and connect 
them to the lamp holder/socket assembly wires.
9.  Reinstall the rear panel to the door assembly.
10. Close the door.
11. Plug-in the new lamp cord assembly to the lamp 
cord connector assembly on top of the dispenser.
12. Refer to Fig. 18 when reconnecting the wires.
FIG. 18 LAMP CORD WIRES
P1926
BLK to WHI
at Lamp Holder
BLK to BLK
at Lamp Holder