Chapter 3: Local Management
3-30
HSIM-F6 User’s Guide
The Interpret 802.3 length for frames > 64 bytes field toggles between the 
following options:
[DISABLED] (default setting)
[ENABLED]
If you retain the default setting of [DISABLED], the HSIM-F6 only 
examines 802.3 frames that are the Ethernet minimum 64 bytes in length. 
This allows for optimal switching performance, as the HSIM-F6 assumes 
all frames over 64 bytes in length contain no padding. 
If this field is set to [ENABLED] the HSIM-F6 examines ALL 802.3 
frame length fields to determine whether any of the frames contain 
padding. In this setting, the HSIM-F6 removes unnecessary padding from 
any 802.3 frame, regardless of the size. Refer to 
information on when to set this field to [ENABLED]
describes how to perform this task.
SAVE
This command saves all configuration changes to memory. 
DEFAULT
This command sets all translation types to their default values.
3.10.2
Setting  Frame Translation Types
To change the frame translations from the default settings, perform the 
following steps:
1.
Use the arrow keys to highlight the desired frame type field, located 
inside the brackets.
2.
Use the SPACE bar to toggle between the available choices.
3.
With the desired frame type selected, use the arrow keys to highlight 
the SAVE command at the bottom of the screen, then press ENTER. 
The “Saved OK” message appears indicating that the changes have 
been saved to memory.