Troubleshooting
Troubleshoot your RF scanning system by performing the following 
checks:
For the RF system, ensure that...
the battery is properly installed. See “Installing the Battery” on 
page 4.
the scanner is within reasonable operating range of the Base 
Station, with no major obstructions between the radio units 
such as thick walls or heavy machinery. (At the time of this 
writing, maximum line-of-sight range is specified at 150 feet.)
there is no local signal interference with other radio-operated 
equipment. Consult the Systems Manual concerning selection 
of alternate channels.
the Base Station is powered-on. You can verify the Base Sta-
tion’s AC Adapter by using a known-good AC Adapter.
the Base Station interface cable is securely attached to the host. 
Consult your technical support manager or refer to your host 
system manual to identify the proper cable connection for the 
scanner. If necessary, verify interface cable function by using a 
known-good interface cable.
If the problem is specific to scanning, verify that...
the bar codes you are trying to scan are of satisfactory quality. 
Bar code label verifiers are available from your dealer if you 
need precise reporting of label details. Bar codes that are dam-
aged (wrinkled, smudged, or torn) may cause the scanner to 
read poorly or not at all. If bar code quality seems to be the 
problem, check to see if the scanner will read a sample bar 
code from the following pages.
the programmable setting for advanced Quadralogic II