Fisher d500243x012 Manual De Usuario

Descargar
Página de 24
1035/El-O-Matic Actuator
Instruction Manual
Form 5417
February 2007
4
Table 3Approximate Weights
ACTUATOR
kg
lbs
ACTUATOR
SIZE
EDA
ESA
EDA
ESA
E25
1.2
1.7
2.7
3.7
E40
1.8
2.4
4.0
5.3
E65
2.4
3.6
5.3
7.9
E100
2.8
4.6
6.1
10.1
E200
5.8
9.1
12.8
20.1
E350
10.4
16.9
22.9
37.3
E600
19.4
27.6
42.8
60.8
E900
26.4
38.6
58.2
85.0
E1600
42.7
65.8
94.1
145
P2500/P2505
56.7
88.0
125
194
P4000/P4005
86.2
132.0
190
291
Table 4. Bolting Torques between 1035 and Yoke
ACTUATOR
SIZE
Bolt Diameter,
Inches
Torque, N
Sm
Torque, lbf
Sft
E25
1/4
11
8.3
E40
E65
E100
5/16
22
16.5
E200
E350
3/8
39
29
E600
1/2
91
67
E950
5/8
163
120
E1600
3/4
258
190
P2500/P2505
P4000/P4005
3/4
203
150
Installation
When an actuator and a valve are shipped together,
the actuator is normally mounted on the valve.
Follow the valve body instructions when installing
the control valve in the pipeline. If the actuator is
shipped separately from the valve or if it is
necessary to mount the actuator on the valve,
perform the procedures in the Actuator Mounting
section.
WARNING
Always wear protective gloves,
clothing, and eyewear when
performing any installation operations
to avoid personal injury.
To avoid personal injury or property
damage caused by bursting of
pressure-retaining parts, be certain the
service conditions do not exceed the
limits given in table 1. Use
pressure-limiting devices or
pressure-relieving devices to prevent
the cylinder pressure from exceeding
these limits.
If hoisting the valve and actuator
assembly or the actuator by itself, take
precautions to prevent people from
being injured in case the hoist or sling
slips unexpectedly. Refer to table 3 for
actuator weights. Carefully position
the sling to prevent damage to tubing
or any accessories.
Check with your process or safety
engineer for any additional measures
that must be taken to protect against
process media.
If installing into an existing
application, also refer to the WARNING
at the beginning of the Maintenance
section in this instruction manual.
Actuator Mounting
Use the following steps to connect a valve and
actuator that has been ordered separately.
The Type 1035 E Series is offered with a Double D
insert as standard to allow direct coupling to the
Type A41 valve drive shaft. A few actuator/valve
combinations will require the use of an external
coupler: E100 with a 1-inch drive shaft, E200 and
E350 with a 1-1/2-inch drive shaft.
P Series applications, the actuators feature an ISO
5211 recessed square drive shaft and requires an
external coupler to engage the valve drive shaft. P
Series actuators also require the use of a Limit Stop
Plate (LSP) if a Type 1080 Declutchable Manual
actuator is not being used.
Assemble the bracket, actuator, LSP (if necessary)
and valve assembly as follows:
1.  Rotate the valve drive shaft to the position
necessary to match the valve/actuator operation.
See figure 3 for mounting style codes and positions.
2.  Attach the yoke/mounting bracket to the actuator
or the LSP (if necessary). Do not fully tighten cap
screws at this time. You will need to align the valve
and actuator, or valve, coupler, LSP and actuator
before tightening the mounting screws to the
required torque. The 5/8-inch screws should not be
used to mount the actuator to the yoke/mounting
bracket. These screws are only to be used for
mounting the LSP. Only the 3/4-inch screws are to