General Safety
Information 
(Continued)
3. Only persons well acquainted with
these rules of safe operation should
be allowed to use the compressor.
4. Keep visitors away and NEVER allow
children in the work area.
5. Wear safety glasses
and use hearing
protection when
operating the pump
or unit.
6. Do not stand on or use the pump or
unit as a handhold.
7. Before each use, inspect compressed
air system and electrical components
for signs of damage, deterioration,
weakness or leakage. Repair or
replace defective items before using.
8. Check all fasteners at frequent
intervals for proper tightness.
Motors, electrical equipment
and controls can cause
electrical arcs that will ignite a
flammable gas or vapor. Never operate
or repair in or near a flammable gas or
vapor. Never store flammable liquids or
gases in the vicinity of the compressor.
Compressor parts may be
hot even if the unit is
stopped.
9. Keep fingers away from a running
compressor; fast moving and hot
parts will cause injury and/or burns.
10. If the equipment should start to
abnormally vibrate, STOP the
engine/motor and check
immediately for the cause. Vibration
is generally a warning of trouble.
11. To reduce fire hazard, keep
engine/motor exterior free of oil,
solvent, or excessive grease.
Never
remove or
attempt to adjust safety valve. Keep
safety valve free from paint and other
accumulations.
Never attempt to repair or
modify a tank! Welding,
drilling or any other
modification will weaken the tank
resulting in damage from rupture or
explosion. Always replace worn or
damaged tanks.
Drain liquid from tank daily.
13. Tanks rust from moisture build-up,
which weakens the tank. Make sure
to drain tank daily and inspect
periodically for unsafe conditions
such as rust formation and
corrosion.
14. Fast moving air will stir up dust and
debris which may be harmful. Release
air slowly when draining moisture or
depressurizing the compressor system.
15. Indoor use only.
16. To reduce the risk of electriccal shock,
do not expose to rain. Store indoors.
SPRAYING PRECAUTIONS
Do not spray flammable
materials in vicinity of open
flame or near ignition
sources including the compressor unit.
16. Do not smoke when spraying paint,
insecticides, or other flammable
substances.
17. Use a face mask/
respirator when
spraying and spray in
a well ventilated area
to prevent health and fire hazards.
18. Do not direct paint or other sprayed
material at the compressor. Locate
compressor as far away from the
spraying area as possible to
minimize overspray accumulation
on the compressor.
19. When spraying or cleaning with
solvents or toxic chemicals, follow
the instructions provided by the
chemical manufacturer.
Installation
LOCATION
It is extremely important to use the
compressor in a clean, well ventilated
area where the surrounding air
temperature will not be more than 100°F.
A minimum clearance of 18 inches
between the compressor and a wall is
required because objects could
obstruct air flow.
Do not
locate the
compressor air inlet near steam, paint
spray, sandblast areas or any other
source of contamination. This debris
will damage the motor.
For Household use only.
GROUNDING INSTRUCTIONS
1. This product is for use on a nominal
120 volt circuit and has a grounding
plug that looks like the plug
illustrated in Fig. 1. Make sure the
product is connected to an outlet
having the same configuration as the
plug. This product must be grounded.
In the event of an electrical short
circuit, grounding reduces risk of
electrical shock by providing an escape
wire for electric current. This product
is equipped with a cord having a
grounding wire with an appropriate
grounding plug. Plug must be
plugged into an outlet that is properly
installed and grounded in accordance
with all local codes and ordinances.
Improper use of grounding
plug can result in a possible
risk of electrical shock!
TEST
RESET
Figure 1 - Grounding Method
Grounding
Pin
Grounded Outlet
Para Ordenar Repuestos o Asistencia Técnica, Sírvase Llamar al
Distribuidor Más Cercano a Su Domicilio
No. de
Numero
No. de
Numero
Ref.
Descripción
de pieza
Ctd.
Ref.
Descripción
de pieza
Ctd.
1
Tapa
1
2
Accesorio de la cubierta
1
3
Interruptor de 
encendido/apagado
FP202833AV
1
4
Tornillo M3 x .15
6
5
Distribuidor
FP202832AV
1
6
Manómetro
FP204012AV
1
7
Válvula de seguridad
V-215102AV
1
8
Amortiguador de goma, 
tornillo, tuerca, arandela
FP202831AV
1
9
Presostato
FP204836AV
1
10
Valvula de chequeo
FP204827AV
1
11
Tornillo M4x0.7x6 
2
12
Tornillo M6x1.0x10 
4
13
Válvula de drenaje
D-1403
1
14
Patas de caucho (Tanque)
FP202828AV
3
15
Cable (interruptor de presión 
a interruptor de corriente)
FP202827AV
1
16
Cordón eléctrico
FP202826AV
1
17
Tornillo M3x10
1
18
Ensamblaje de bomba/motor
FP202824AV
1
19
Cubierta del motor
1
20
Cubierta del extremo
1
21
Soporte de goma
1
22
Patas de caucho (motor)
3
23
Sujetador del cable
FP202823AV
1
24
Alivio de tensión
FP202822AV
1
25
Kit de tubo de escape
FP202839AV
1
JUEGOS DE REPUESTOS
Juego de la cubierta
FP202834AV
Juego de la cubierta del motor FP202835AV
Juego de patas de caucho
FP202836AV
Juego para calcomanía
FP202837AV
Artículo estándar de ferretería
Liste de Repuestos
FP202800
16
1
20
19
14
13
22
2
8
9
10
12
4
7
6
5
3
17
15
11
24
21
23
22
25
18
Dirija toda la correspondencia a:
Customer Service
100 Production Drive
Harrison, OH  45030 U.S.A.
Sírvase darnos la siguiente información:
-Número del modelo
-Número de Serie (de haberlo) 
-Descripción y número del repuesto según