Figure 6.5 Clear command sequence
P S S
B P T
B P T
B B
1 1 0 0 0 0 0 0
S
T
B
T
B
0 0 0 0 0 0 0 0
0 0 1 0 0 0 1 0
P S S
B P T
B P T
B B
H
L
RXD
H
L
TXD
H
L
CTS
H
L
RTS
H
L
DTR
H
L
DSR
P S
B P
B P
B
Sequence 1
t
2
1 1 1 1 1 1 1 1
S
T
B
T
B
P S
B P
B P
B
0 1 0 0 0 0 0 0
S
T
B
T
B
P S S
B P T
B P T
B B
0 1 0 0 1 0 1 0
P S
B P
B P
B
t
1
Sequence 2
1 1 1 1 1 1 1 1
S
T
B
T
B
P S
B P
B P
B
t
3
Sequence 3
Sequence 4
Note 1
t
2
t
3
t
1
: more than 1 word length (changed by data transfer rate)
t
2
: less than 500 ms
t
3
: less than 5 s
Sequence 1:
The host computer sends the CLEAR command to the scanner.
X`03', `44', `00'
Sequence 2:
ACK for the CLEAR command is sent to the host computer.
X`FF'
Sequence 3:
Response for the CLEAR command is sent to the host computer.
X`02', `52'
Sequence 4:
ACK for the response (issued at Sequence 3) is sent to the scanner.
X`FF'
Note 1:
During the CLEAR command execution, DTR signal takes low level.