2.2  Replacing the Fuse 
The fuse (5 A) in the power cable protects the equipment against reverse polarity of ship’s 
mains, overcurrent, and equipment fault. If the fuse blows, find the cause before replacing it.   
 
Use the proper fuse.
Use of a wrong fuse may cause 
serious damage to the equipment
and void the warranty.
CAUTION
 
 
 
2.3 Troubleshooting 
The table below provides simple troubleshooting procedures which the user can follow to 
restore normal operation. If you cannot restore normal operation contact your dealer for advice. 
Troubleshooting 
If… But… Then… 
nothing appears on the 
display or display contrast 
is poor 
• try adjusting LCD contrast. 
• battery may have discharged. 
• check if fuse has blown. 
you pressed the 
[POWER/BRILL] key to turn on 
the radar 
the control panel does not 
light 
adjust PANEL DIMMER on the   
User menu. 
the message “NO 
HEADING PULSE” or “NO 
BEARING PULSE” 
appears  
check that the antenna cable is 
firmly connected. 
the radar has warmed up and 
you pressed the [MODE] key to 
transmit 
neither noise or targets 
appear (characters and 
markers do) 
• 
try adjusting gain, A/C SEA and 
A/C RAIN. 
• 
check signal cable for damage. 
a key is pressed 
nothing happens 
key may be faulty. Contact your 
dealer. 
the display freezes 
 
Press the [MENU/ESC] key about 
five seconds to turn off the power 